iPlex Installation and Hardware Specification Guide
39
Indicators
RDY
—Ready Green LED
ACT
—Active Green LED
ASIOut
Submodule
The ASIOut submodule is distinguished by its label (ASIOUT) and by an orange
line around the BNC connectors. Looking at the interface view of the card, you
can see BNC connectors and activity LEDs.
Specifications
Mechanical
Height:
0.509 inches
Width:
2.913 inches
Depth:
5.866 inches
Connectors:
BNC
Indicators
RDY
—Ready Green LED
ACT
—Active Green LED
State
RDY
ACT
Power Off
Off
Off
LED test for approximately 8 seconds,
following power up and board configu-
ration.
On
On
ASI In Port disabled
Flash-
ing
Off
ASI In Port enabled, no ASI In traffic
On
Off
ASI In Port enabled, ASI In traffic
On
Flash rate proportional
to MPEG TS packet rate
RDY ACT
RDY ACT
ASI OUT
1A
1B
2A
2B