Site Preparation
1.15
External Timing Cables
An external timing cable provides a connection from an external synchronization
source, such as a building integrated timing supply (BITS) or synchronization
supply unit (SSU), to the SmartEdge 600 router. Using two cables you can
connect the SmartEdge 600 router to primary and secondary inputs on the
external equipment.
Table 15
Cable Specification for External Timing Cable
Interface
Description
Chassis Connectors
(1)
Cable Connector
External Timing
Shielded twisted-pair
DB-9 female
DB-9 male
(1) The chassis connectors are on the rear of the chassis.
A cable consists of two individually shielded, twisted-wire pairs: one pair for the
synchronization input and another pair for the synchronization output.
Note:
The XCRP4 Controller card can receive timing data only.
The nominal impedance of the DS-1 wire pairs is 100 ohms; that of the E1
wire pairs is 120 ohms.
One end of the cable is terminated with a DB-9 male connector; the other
end of the cable is left unterminated for attachment to the wire wrap posts
of the external equipment. Both of the DB-9 connectors (PRIMARY and
SECONDARY) on the rear panel of the SmartEdge 600 router have identical
pin assignments.
Note:
An adapter, available as an option, provides wire wrap pins to allow you
to attach a cable without a connector.
To bring a signal from external equipment into the SmartEdge 600 router:
•
For the DS-1 interface (BITS)—Connect the DS-1 output of the external
equipment to pins 2 and 6 of the DB-9 connector on the rear panel of the
router. The polarity of the signal does not matter. The router accepts a
standard BITS source transmitting a framed-all-ones pattern at the DS-1
rate of 1.544 Mbps.
•
For the E1 interface (SSU)—Connect the E1 output of the external
equipment to pins 2 and 6 of the SSU DB-9 connector on the rear panel
of the router. The polarity of the signal does not matter. The router
accepts a standard synchronization source transmitting an HDB3-encoded,
framed-all-ones pattern at the E1 rate of 2.048 Mbps.
Table 16
External Timing Cable Pin Assignments
Signal Name
(1)
Color
Notes
Shield
Bare Wire
Frame ground connection
External equipment input (+)
White
Twisted pair with pin 6
–
–
No connection
15
27/153 30-CRA 119 1170/1 Uen A
|
2010-04-09
Summary of Contents for SmartEdge 600
Page 1: ...SmartEdge 600 Router Hardware Guide Release 6 3 INSTALLATION 27 153 30 CRA 119 1170 1 Uen A ...
Page 6: ...SmartEdge 600 Router Hardware Guide 27 153 30 CRA 119 1170 1 Uen A 2010 04 09 ...
Page 26: ...SmartEdge 600 Router Hardware Guide 20 27 153 30 CRA 119 1170 1 Uen A 2010 04 09 ...
Page 108: ...SmartEdge 600 Router Hardware Guide 102 27 153 30 CRA 119 1170 1 Uen A 2010 04 09 ...
Page 112: ...SmartEdge 600 Router Hardware Guide 106 27 153 30 CRA 119 1170 1 Uen A 2010 04 09 ...