Operating the Equipment Remotely
Table 4.2 Configuring the Serial Remote Port and Activating Remote Protocol
Step Action
Result
1.
Go to menu 7.1.
Displays ‘OPERATING MODE’.
2. Press
Edit
.
Displays ‘FRONT PANEL’.
3.
Press the down pushbutton
and select ‘SERIAL REMOTE’.
The settings should be set to match the external
control host.
4. Press
Save.
The unit is ready for Remote Control.
Once the communication parameters are entered correctly, set the system into
remote mode for the external computer to gain control of the unit:
Step Action
Result
1.
Go to menu 7.1.2.
Displays ‘SERIAL REMOTE PROTOCOL’.
2. Press
Edit.
Toggle between RS-232 Alteia or RS-485 Alteia.
3.
Chose between RS-232 Alteia
or RS-485 Alteia.
The settings should be set to match the external
control host.
4. Press
Save.
The unit is ready for Remote Control.
4.1.5
Configuring the Unit for Remote Control Over-air
4.1.5.1
Overview
For the unit to be controlled via over-air control (OAC), the control mode of the Multi-
Format Receiver needs to be set to Director NCP.
Table 4.3 Activating Director NCP Remote Control
Step Action
Result
1.
Go to menu 7.1.
Displays ‘OPERATING MODE’.
2. Press
Edit.
Displays ‘FRONT PANEL’.
3.
Press the down pushbutton
and select ‘DIRECTOR NCP’.
The settings should be set to match the external
control host.
4. Press
Save.
The unit is ready for OAC.
4.1.5.2
OAC Lockout
Once the unit is in OAC control mode, it is possible for the remote control operator
to issue a local lockout command to the Receiver. This will effectively deny the local
user access to configuring the unit.
EN/LZT 790 0003/2 R1A
4-4
Summary of Contents for RX1290
Page 22: ...Introduction EN LZT 790 0003 2 R1A 1 14 BLANK...
Page 42: ...Operating the Equipment Locally EN LZT 790 0003 2 R1A 3 4 BLANK...
Page 68: ...Operating the Equipment Remotely EN LZT 790 0003 2 R1A 4 2 BLANK...
Page 72: ...Operating the Equipment Remotely EN LZT 790 0003 2 R1A 4 6 BLANK...
Page 74: ...Alarms EN LZT 790 0003 2 R1A 5 2 BLANK...
Page 88: ...Preventive Maintenance and Fault finding EN LZT 790 0003 2 R1A 7 2 BLANK...
Page 142: ...Technical Specification EN LZT 790 0003 2 R1A B 28 BLANK...
Page 146: ...Menus EN LZT 790 0003 2 R1A C 4 BLANK...
Page 153: ...Menus Menus EN LZT 790 0003 2 R1A C 11 EN LZT 790 0003 2 R1A C 11...
Page 168: ...Menus EN LZT 790 0003 2 R1A C 26 BLANK...
Page 170: ...Language Abbreviations EN LZT 790 0003 2 R1A D 2 BLANK...