2.
When a group on the scan list receives
a channel assignment, the radio un-
squelches on the assigned channel and
the group name is displayed.
The radio will continue scanning if a new
group is selected when scan is on.
Pressing the PTT BUTTON when scan
is on will cause the radio to transmit on
the selected group.
A "nuisance" group can be deleted from
the scan list by pressing
@
A/D while
the radio is receiving the "nuisance" call.
The group will be deleted from the scan
list. Add the group back to the scan list
by turning the radio off and back on or
by turning scan off, selecting the group,
and pressing
@
A/D.
3. Toggle scan operation off by pressing
s
. The radio will resume operation on
the selected group.
Special Calls
Special calls include individual and telephone
interconnect calls. Up to 99 different special calls
can be programmed into the radio and selected
for transmission.
Receiving An Individual Call
When an individual call (a call directed to only
one radio) is received, the radio will unsquelch on
the assigned channel and the BSY status flag will
turn on. *INDV*, originators ID, or the caller’s
name (if programmed) is displayed and the MSG
status flag flashes. Adjust the volume as neces-
sary.
Responding to an individual call prior to the
programmed call-back time-out will automatically
direct the transmission to the originating unit.
Follow the instructions for sending a special call.
If the call is not answered, the "MSG" status
flag will remain flashing even after the individual
call time-out period expires. Press
P
(SPecial
Call) to call the originating unit back. The origina-
tor’s ID or name will be displayed.
25