8.2
Error messages on the display
Display
Cause
Rectification
The control box compact-3-eco is
equipped with an overheating protec-
tion. This overheating protection will
activate due to too high temperatures.
Wait until the control box has cooled down and the
message
HOT
is no longer displayed. Then the
control box is ready for operation again.
There is an internal error at the control
box compact-3-eco.
Proceed according to the following error list.
00
Internal error channel 1
Disconnect the power cable from the mains and
contact the customer service.
01
Internal error channel 2
12
Defective channel 1
The motor cable is not plugged-in correctly.
13
Defective channel 2
24
Excess current motor M1
System overloaded
Remove load from the sys-
tem
System jammed
remove clamped object
25
Excess current motor M2
48
Excess current motor group 1
49
Excess current motor group 2
60
Collision protection
62
Excess current control
36
Plug detection at motor socket M1
Plug in the motor cable correctly at the respective
socket.
Reset the system.
37
Plug detection at motor socket M2
61
Motor replaced
55
Synchronising of the motor group 1
impossible
Remove load from the system. Reset the system.
Contact the customer service if the error remains
displayed.
56
Synchronising of the motor group 2
impossible
67
Too high voltage
Disconnect the power cable from the mains.
Contact the customer service.
70
Change of the drive configuration
Disconnect the power cable from the mains and
wait at least for 5 seconds. Reconnect the power
cable and reset the system.
81
Internal error
Disconnect the power cable from the mains and
wait at least for 5 seconds. Reconnect the power
cable and reset the system.
Contact the customer service if the error remains
displayed.
93
Connection error while synchronising
The error is displayed for 15 seconds,
then the control box changes to the
reset mode with a flashing display of
000
.
Disconnect the power cable from the mains and
wait at least for 5 seconds. Reconnect the power
cable and reset the system.