background image

9

ErgoSafe AB | Reparatörgatan 1 | SE-302 62 Halmstad | +46 (0)10-480 47 00 | www.ergosafe.se

by

 

 

Declaration of Performance for 

ClickitUp®Balcony 

 

Product: 

Balcony system 

Intended use: 

Personal protection Balcony 

 

Manufacturer: 

ERGOSAFE 

Reparatörgatan 1 

30262 Halmstad, Sweden 

Systems of attestation of 

conformity: 

2+ 

Notified body: 

SP AB 

Notified body no.: 

0402 

 

Has performed an initial audit and assessment of factory production control as well as performed the ongoing 

supervision of factory production control and has issued certificates for factory production control (FPC) no.: 

0402-CPR - SC1078-15 

Essential characteristics 

Performance 

Harmonised technical specification 

Geometric data (tolerances for 

dimensions and form) 

EN 1090-1, tolerance class 1 

EN 1090-3 annex G 

Weldability 

NPD 

 

Fracture toughness 

NPD 

 

Reaction to fire 

Material class A1 

EN 13501-1 

Release of Cadmium 

NPD 

 

Radioactive radiation 

NPD 

 

 

Durability 

Surface treatment according to 

1090-2, degree of pre-treatment P3. 

Surfaces painted according to EN 

ISO 12944. 

EN 1999-1-1 

Deformation in serviceability limit 

state 

<30 mm at full load 

EN 1090:2009+A1:2011 

Execution classification 

EXC2 

EN 1090-3 Annex G 

Fire resistance 

NPD 

 

Ultimate bearing strength 

characteristics 

NPD 

 

Fatigue 

NPD 

 

This declaration of performance is issued under the sole responsibility 

of ErgoSafe AB. Signed for and on behalf of the manufacturer by: 

 

Halmstad 17/12/2016 

 

Fredrik Johansson, CEO 

Summary of Contents for ClickitUp CiU BalconyFixed

Page 1: ...Instruction Manual CiU BalconyFixed by...

Page 2: ...product is design protected by Ergo Safe AB AB Design right 002416248 001 005 3 3 2014 Contents Safety 3 Reception unloading 3 Installation 4 Preparationspriortoinstallation 4 Installation 5 Technica...

Page 3: ...not possible to cite discrepancies regarding the delivery of CiU Fixed Balcony UNLOADING FROM PALLETS Note that unloading must be performed in a specific order otherwise personal injury can occur Ther...

Page 4: ...ng to install CiU Fixed Balcony Each CiU Fixed Balcony section is delivered ready assembled Sections are linked together to form a system with the help of double cover caps and double baseplate mounts...

Page 5: ...if the ground slopes the posts will be in their bottom position at the ground s highest point Any adjustments are made as per figure 3 If corners are to be installed start with this Place the first s...

Page 6: ...spirit level Screws are included for fastening sections 6 Fitting permanent caps Now to the finish of the CiU Fixed Balcony installation Fit the permanent cover caps single or double Exercise care to...

Page 7: ...ng is used to fit the glass to the aluminium posts Baseplate mounts As standard there are baseplate mounts which are double or single cover caps cover caps are available as double and single mounts Ma...

Page 8: ...oking the warranty the product s serial number must be stated as well as any pictures that clarify what is being claimed on the warranty C When exchanging parts these must unconditionally be returned...

Page 9: ...stics Performance Harmonised technical specification Geometric data tolerances for dimensions and form EN 1090 1 tolerance class 1 EN 1090 3 annex G Weldability NPD Fracture toughness NPD Reaction to...

Page 10: ...10 by...

Page 11: ...11 ErgoSafe AB Reparat rgatan 1 SE 302 62 Halmstad 46 0 10 480 47 00 www ergosafe se by...

Page 12: ...ErgoSafe AB Reparat rgatan 1 SE 302 62 Halmstad 46 0 10 480 47 00 www ergosafe se Copyright 2015 ErgoSafe AB...

Reviews: