Step
Possible Cause
If . . .
12a
Is there 12Vdc between bottom terminal of
circuit breaker (red wire) and nearby ground
source (black wire)?
•
Yes, replace circuit breaker.
•
No, go to Step 13.
13
Is there 12Vdc between “ACC” (red wire) of
ignition switch and nearby ground source
(black wire)?
•
Yes, check for loose or broken wires
between “ACC” of ignition switch and
bottom terminal of circuit breaker.
•
No, go to Step 13a.
13a
Is there 12Vdc between “B” (blue wire) of
ignition switch and nearby ground source
(black wire)?
•
Yes, replace ignition switch.
•
No, go to Step 14.
14
Is there 12Vdc between blue wire on starter
solenoid and nearby ground source (black
wire or bare metal on engine case)?
•
Yes, check for loose or broken wire
between starter solenoid and ignition
switch.
•
No, go to step 14a.
14a
Check connections and condition of red
battery cable.
•
Yes, there should be 12Vdc at all previous
steps.
•
No, replace battery cable.
Table 8-12 Burner Electrical Troubleshooting – 3C Engine (continued)