How to use this device
72/96
–
Remove the screws and then remove the lamp cover.
The following components listed in the maintenance plan are fitted in the
canopy:
Low pressure lamps
High pressure lamps
Facial tanner filter panels
Facial tanner low pressure lamps and the associated starters
Replacing lamps:
Low pressure lamps: see page 67.
High pressure lamps and filter panels: see page 69.
Replacing starters: see page 68.
Model-No.: JK 155 / 46-3 AC:
These devices have 2 low pressure lamps in the facial tanner.
The facial tanner's low pressure lamps must be removed first so that the high
pressure lamps and the filter panels can be changed.
–
Remove the lamps.
–
Remove the two upper low pressure lamps in the canopy so that you can
then access the facial tanner's low pressure lamp starter.
Replacing lamps: see page 67.
Replacing starters: see page 68.
High pressure lamps and filter panels: see page 69.
The assembly is the same process in reverse order.
When assembling the device please note:
–
Support the canopy panel with one hand so that it does not fall down.
–
Re-lock the locks: first the lock in the middle, then the outer locks.