1

English

- Our continually updated product 

documentation can be accessed at 

www.erco.com/download. 

- Please read these instructions carefully 

before installation and commissioning 

and hand over to the customer for 

retention.

General safety information

 Warning! Risk of electric shock!

    Before carrying out maintenance 

and installation on the luminaire, 

disconnect from the mains supply and 

ensure that all power is switched off.

- To avoid risks, if this luminaire has a 

damaged external flexible cable, it must 

only be replaced by the manufacturer, 

his service agent or qualified technician.

- When installing, always observe the 

national installation and accident pre-

vention regulations.

Safety glass

Increased danger of slipping or skidding 

on glass when wet.

The luminaire must only be used com-

plete with its protective shield. 

Loading on the safety glass

The safety glass used can withstand a 

load of 5kN, if caused by people step-

ping onto the recessed floor luminaire.

Loads caused by hard objects, by impacts 

or blows must always be avoided.

X

 Y

 A damaged safety glass 

must be replaced.

Surface temperature of safety glass 

Please note that the surface tempera-

ture will be raised by 30°C.

Due consideration must be given to the 

surface temperature of the glass at the 

planning stage.

IP67

The luminaire is dust- and watertight. It 

is protected against the consequences 

of submersion.

If there is a danger of flooding then 

suit able drainage must be provided.

Intended use

- Nadir recessed floor luminaires are 

only suitable for use in indoor areas.

- These luminaires are generally 

installed in separately pre-installed 

housings, mounting frames or moun-

ting rings.

Choosing the mounting location

The luminaire must be positioned so as to 

avoid operation in direct sunlight or near 

other sources of heat. High ambient tem-

peratures can reduce the life and efficien-

cy of the control gear or LED module.

Electrical installation

To avoid any damage to the electronic 

control gear on a 3-circuit installation, 

the neutral conductor of electronic 