EG_GenPro53e_1040_UG_003_UK
Page 56 / 71
Descriptions and non-contractual illustrations in this document are given as an indication only.
ERCO&GENER reserves the right to make any modifications
For example:
The equipment is supplied with 12V with
- the battery charged
- RS 232 connected
- The GSM module in GPRS communication at 900 MHz
I Nom.(mA)
I Pic.(mA)
Board
28
RS
3.2
GSM
191.3 804
Total :
222.5
804
The average consumption is 222.5 mA and the power supply must support current peaks of 804 mA.
The equipment is supplied with 12V with
- The battery charging
- RS 232 connected
- The GSM module in GPRS communication at 900 MHz
I Nom.(mA)
I Pic.(mA)
Board
28
Battery
122.6
RS
3.2
GSM
191.3 804
Total :
345.1
804
The average consumption is 345.1 mA and the power supply must support current peaks of 804 mA.
8.2.1.1 Consumption of the board with battery charged
Table: Consumption of the board with battery charged
CONDITIONS
+VDC
I Nom.(mA)
T=25°C
Battery charged
@ 5,5V
50
GSM OFF
@ 12V
28
RS 232 disconnected
@ 24V
17
@
32V
14
(1*) The consumptions of the power supply may vary by 5% depending on the temperature range (-20 °C to +55 °C).
8.2.1.2 Consumption of the board with battery charging
Table: Consumption of the board with battery charging
CONDITIONS
+VDC
I Nom.(mA)
T=25°C
Battery charging
@ 5,5V
295
GSM OFF
@ 12V
151
RS 232 disconnected
@ 24V
84
@
32V
66
(1*) The consumptions of the power supply may vary by 5% depending on the temperature range (-20 °C to +55 °C).