Order code: EQLED054

Fusion 200 Zoom Spot 

User Manual

Summary of Contents for Fusion 200 Zoom Spot

Page 1: ...Order code EQLED054 Fusion 200 Zoom Spot User Manual...

Page 2: ...ill reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleani...

Page 3: ...a protective earthing connection Risk group 2 RG 2 CAUTION Do not stare at exposed LED in operation as it may damage be harmful to the eyes Avoid looking directly into the light source CAUTION If the...

Page 4: ...ng and variable strobe Quick release omega clamps included 4 push button menu with 2 6 LCD display PowerCON input output 3 Pin XLR input output Fan cooled Fusion 200 Zoom Spot Specifications Fusion 20...

Page 5: ...www prolight co uk Fusion 200 Zoom Spot User Manual 5 Technical specifications 355mm 450mm 274mm 405mm 293mm 302mm 96mm 183mm 200mm 96mm...

Page 6: ...cations 01 LCD display 02 Function buttons 03 3 Pin DMX input 04 3 Pin DMX output 05 PowerCON input 06 PowerCON output 07 Fuse F4A 250V 08 Power switch 09 Carry handles In the box 1 x fixture 2 x omeg...

Page 7: ...the material being used at the installation area and periodic safety inspections of the fixture and installation material If you do not have the relevant experience and or qualifications please do no...

Page 8: ...clamp quick lock fasteners with the respective holes on the bottom of the unit 3 Tighten both locking fasteners clockwise on each omega clamp ensuring they re fully secure 4 Mount the fixture onto yo...

Page 9: ...t The fixture will then return to its home screen Pressing the ENTER button once will take the user to the fixtures main menu Using the UP and DOWN buttons you can then navigate between the different...

Page 10: ...the ENTER button and use the UP and DOWN buttons to show Channel Mode on the LCD display Now press the ENTER button and use the UP and DOWN buttons to set the required DMX channel Press the ENTER butt...

Page 11: ...und Sensitivity xxx Slave 1 On Default 080 Slave 2 Sound mode To access the sound mode setting press the ENTER button and use the UP and DOWN buttons to show Sound on the LCD display Now press the ENT...

Page 12: ...he LCD display Press the ENTER button and use the UP and DOWN buttons to select the various options Press the ENTER button and use the UP and DOWN buttons to select between 000 255 Press the ENTER but...

Page 13: ...Sets what the fixture does when the DMX signal is lost To access the DMX fail setting press the ENTER button and use the UP and DOWN buttons to show DMX Fail on the LCD display Now press the ENTER but...

Page 14: ...P and DOWN buttons to select Backlight Press the ENTER button and use the UP and DOWN buttons to select between Off and On Press the ENTER button to confirm the setting Display invert To access the di...

Page 15: ...ess the ENTER button and use the UP and DOWN buttons to select between 000 255 Press the ENTER button to confirm the setting Please note Calibration settings are set when the fixture is manufactured T...

Page 16: ...the fixtures motors To access the motor reset setting press the ENTER button and use the UP and DOWN buttons to show Motor Reset on the LCD display Press the ENTER button and use the UP and DOWN butto...

Page 17: ...settings To access the factory setting reset press the ENTER button and use the UP and DOWN buttons to show Factory Reset on the LCD display Press the ENTER button and use the UP and DOWN buttons to...

Page 18: ...een 059 067 Split colour Green Blue 068 076 Blue 077 085 Split colour Blue Yellow 086 094 Yellow 095 103 Split colour Yellow Cyan 104 112 Cyan 113 121 Split colour Cyan Magenta 122 130 Magenta 131 139...

Page 19: ...change gobo change 201 240 No function 241 255 Motor reset hold 10s 14 channel mode cont Channel Value Function CH7 cont 078 087 Gobo 1 shake slow fast 088 097 Gobo 2 shake slow fast 098 107 Gobo 3 s...

Page 20: ...00 007 Open 008 017 Gobo 1 018 027 Gobo 2 028 037 Gobo 3 038 047 Gobo 4 048 057 Gobo 5 058 067 Gobo 6 068 077 Gobo 7 Channel Value Function CH9 cont 078 087 Gobo 1 shake slow fast 088 097 Gobo 2 shake...

Page 21: ...3 No function 134 255 Gobo wheel scroll CCW slow fast CH16 000 015 No function 016 075 Show 1 076 135 Show 2 136 195 Show 3 196 255 Show 4 forward facing show CH17 000 255 Sound sensitivity low high C...

Page 22: ...ng all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data tran...

Page 23: ...cable adaptor must be used The diagram below details the correct cable conversion 5 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 pin XLR female Pin 1 GND screen Pin...

Page 24: ...s that can be connected is 6 fixtures 240V or 3 fixtures 120V including the first fixture After the maximum number of fixtures are connected a new power run will need to be started Please note Caution...

Page 25: ...ossible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material...

Page 26: ...www prolight co uk Fusion 200 Zoom Spot User Manual 26...

Page 27: ...www prolight co uk Fusion 200 Zoom Spot User Manual 27...

Page 28: ...www prolight co uk Fusion 260ZR User Manual 28...