30
Equinox ESP-2 OPTO Serial Hub Installation and User Guide
5.10 Rebooting the Hub
The Reboot operation reboots the ESP-2 serial hub. A reboot is usually required for
the following operations to take effect:
•
Changing network address values
•
Changing any configurable features
•
Updating FLASH
To reboot:
1. From the Top Menu, enter
0
to select Server Configuration.
2. From the Server Configuration menu, enter
5
to select Reboot.
You may also reboot the ESP-2 serial hub using the web interface (see
on page 22) or the RESET button on the front panel (see
5.11 Reinitializing the Hub
The Reinitialize command resets all configurable values to their factory defaults,
including the IP address and password.
To reinitialize:
1. From the Top Menu, enter
0
to select Server Configuration.
2. From the Server Configuration menu, enter
7
to select Re-Initialize (factory defaults).
You may also reinitialize the ESP-2 serial hub using the web interface (see
on page 23) or the INIT button on the front panel (see
5.12 Displaying General Statistics
The General Statistics display includes the items described in Table 15 on page 20.
All values are cumulative since the ESP-2 serial hub was last reset.
To display general statistics:
1. From the Top Menu, enter
3
to select Status.
2. From the Status Menu, enter
1
to select General statistics.
5.13 Displaying Port Statistics
The Port Statistics display includes the information described in Table 16 on page 21
for each port.
All values are cumulative since the ESP-2 serial hub was last reset.
To display port statistics:
1. From the Top Menu, enter
3
to select Status.
2. From the Status Menu, enter
2
to select Port statistics.