Equinox Systems EQLED034 User Manual Download Page 7

www.prolight.co.uk

Quad Pix Batten

  

User Manual

7

Operating instructions

 

 

 

 

 

Static colour mode:

To access the static colour mode press 

“MENU”

 until  

CoLr

 shows on the LED display.  

Now press the 

“ENTER”

 button and use the 

“UP”

 and 

“DOWN”

 buttons to select the brightness  

between  

r.000

 ~ 

r.255

. Press the 

“ENTER” 

button and repeat for green (

G

), blue (

b

) and white (

u

).

Value: 000 - 255 (000 = low brightness, 255 = high brightness)

To exit out of any of the above options, press the 

“MENU”

 button. 

Built-in programs:

To access the built-in programs, press the 

“MENU”

 button on the front of the unit to show  

Pr--

  

on the LED display. Now press the 

“ENTER”

 button and use the 

“UP”

 and 

“DOWN”

 buttons to choose the 

required program  

Pr01

 ~ 

Pr16

. Press the 

“ENTER”

 button to confirm the setting.

 
Pr01

  - Now use the 

“UP”

 and 

“DOWN”

 buttons to select the required colour. Press the 

“ENTER”

 

button to confirm the setting and use the 

“UP”

 and 

“DOWN”

 buttons to choose the flash speed   

F500

 ~ 

F599

. Press the 

“ENTER”

 button to confirm the setting.

Pr02

 ~ 

Pr16

 - Now use the 

“UP”

 and 

“DOWN”

 buttons to select the running speed  

SP01

 ~ 

SPFL

. Press the 

“ENTER”

 button to confirm the setting. Now use the 

“UP”

 and 

“DOWN”

 

buttons to select the flash speed 

F500

 ~ 

F599

. Press the 

“ENTER”

 button to confirm the setting. 

Finally use the 

“UP”

 and 

“DOWN”

 buttons to select the fading time 

Fd00

 ~ 

Fd99

.  

Press the 

“ENTER”

 button to confirm the setting.

To exit out of any of the above options, press the 

“MENU”

 button.

48 channel mode:

CH1

CH2

CH3

CH4

CH5

CH6

CH7

CH8

CH9

CH10

CH11

CH12

R1 

(0-100%)

G1 

(0-100%)

B1 

(0-100%)

W1 

(0-100%)

R2 

(0-100%)

G2 

(0-100%)

B2 

(0-100%)

W2 

(0-100%)

R3 

(0-100%)

G3 

(0-100%)

B3 

(0-100%)

W3 

(0-100%)

CH13

CH14

CH15

CH16

CH17

CH18

CH19

CH20

CH21

CH22

CH23

CH24

R4 

(0-100%)

G4 

(0-100%)

B4 

(0-100%)

W4 

(0-100%)

R5 

(0-100%)

G5 

(0-100%)

B5 

(0-100%)

W5 

(0-100%)

R6 

(0-100%)

G6 

(0-100%)

B6 

(0-100%)

W6 

(0-100%)

CH25

CH26

CH27

CH28

CH29

CH30

CH31

CH32

CH33

CH34

CH35

CH36

R7 

(0-100%)

G7 

(0-100%)

B7 

(0-100%)

W7 

(0-100%)

R8 

(0-100%)

G8 

(0-100%)

B8 

(0-100%)

W8 

(0-100%)

R9 

(0-100%)

G9 

(0-100%)

B9 

(0-100%)

W9 

(0-100%)

CH37

CH38

CH39

CH40

CH41

CH42

CH43

CH44

CH45

CH46

CH47

CH48

R10 

(0-100%)

G10 

(0-100%)

B10 

(0-100%)

W10 

(0-100%)

R11 

(0-100%)

G11 

(0-100%)

B11 

(0-100%)

W11 

(0-100%)

R12 

(0-100%)

G12 

(0-100%)

B12 

(0-100%)

W12 

(0-100%)

Summary of Contents for EQLED034

Page 1: ...Order code EQLED034 Quad Pix Batten User Manual...

Page 2: ...n short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is...

Page 3: ...capabilities DMX channels 3 4 6 or 48 selectable Static colour auto sound active and master slave modes plus built in programs 0 100 dimming and variable strobe Bracket allows for multiple rigging or...

Page 4: ...PIX BATTEN POWER INPUT 100 240V 50 60Hz FUSE T1A 250V MENU ENTER UP DOWN POWER OUTPUT DMX INPUT DMX OUTPUT MENU ENTER UP DOWN POWER OUTPUT DMX INPUT DMX OUTPUT QUAD PIX BATTEN POWER INPUT 100 240V 50...

Page 5: ...odes S _ 0 0 S 0 0 S _ 3 1 S 3 1 S _ 0 0 S _ 3 1 Auto mode A u t 0 n 0 0 1 s P 0 0 n 1 0 0 S P F L F 5 0 0 F 5 9 9 MENU d 0 0 1 DMX address setting channel mode d 0 0 1 d 5 1 2 3 c h 4 c h 6 c h 4 8 c...

Page 6: ...DMX channel modes Press the ENTER button to confirm the setting To exit out of any of the above options press the MENU button Value CH1 CH2 CH3 000 No function No function No function 001 014 Program...

Page 7: ...o confirm the setting Pr02 Pr16 Now use the UP and DOWN buttons to select the running speed SP01 SPFL Press the ENTER button to confirm the setting Now use the UP and DOWN buttons to select the flash...

Page 8: ...s now in Slave mode To exit out of any of the above options press the MENU button Please ensure that all slave units are set to the same DMX channel mode as the master unit Sound active mode To access...

Page 9: ...from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX linking DMX is a language allowing all makes and mode...

Page 10: ...5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin...

Page 11: ...prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse o...

Page 12: ...www prolight co uk Quad Pix Batten User Manual 12...