EQAS AS-5 Series Installation & Operation Manual Download Page 1

 1 

 

 

 

 

           

Installation, Operation, and Service Procedures 

 

 EQAS AS-5 heaters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

General 

Description 

 

This booklet covers EQAS AS-5 series heaters. They are designed to be used only 

with baptismal pools manufactured by Fiberglass Specialties, Inc. 

 

The EQAS AS-5 replaces the EQAS H-5, S-5, H-11 & S-11 models.  This replacement 

was necessary to keep aligned with current building codes.  

 

 

HEY!  

Adjust the System Timer by turning the dial 

 clockwise only.

  Do not attempt to 

turn the Timer counter clockwise or permanent damage to the Timer will occur. 

 

Note:  These systems are designed for use with municipal water systems.  The  

warranty for all products (including the pool)  is void if any non-potable water is used in 

the pool.   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8/2014 

Fiberglass Specialties, Incorporated 

500 Austin Ave.  Henderson, TX 75652 

800-527-1459 

www.FSIWEB.com 

Summary of Contents for AS-5 Series

Page 1: ...ement was necessary to keep aligned with current building codes HEY Adjust the System Timer by turning the dial clockwise only Do not attempt to turn the Timer counter clockwise or permanent damage to...

Page 2: ...pter GFCI A green colored terminal is provided within the terminal compartment To reduce the risk of electric shock connect this terminal to the grounding terminal of your electric service or supply p...

Page 3: ...to prevent excessive turbulence Flow Control valves red handles are included but not required for installation These valves should be placed in the suction and return lines so water from the baptistr...

Page 4: ...hillips head screws from the top of the front cover of the heater and hinge the cover for ward Note the location of the terminal block inside the heater The ter minals on the block are marked Line 1 L...

Page 5: ...5 SYSTEM INTERFACE MODULE Module Connections Auto Water Fill Auto Drain Air Button Water Level Control...

Page 6: ...Teflon tape on all threaded connections Installation of the Auto Drain 3 PIN Connector Following the baptistry installation instructions for location install the floor drain In a convenient location p...

Page 7: ...ther convenient location The air button in the heater package allows for NON ELECTRICAL start stop of the system and will override the time clock function System operation is paused but live electrica...

Page 8: ...ock The system includes a 7 day time clock to allow for automatic control of the system Set the system timer by turning the outer dial clockwise only until the present time and day are aligned with th...

Page 9: ...ub panel circuit breaker Set to on position GFCI tripped Set to on position Components not plugged in Plug in all components Time Clock has turned system off Adjust time clock Overheat Protection Swit...

Page 10: ...IR BUTTON 1 PARTS BAG C O Bonding wire 8 self tapping screws 8 washers System Interface Module 1 System Controller 1 Air Button 1 10 tubing Pressure Switch Module 1 Pressure switch w cable 1 Wall fitt...