background image

Operating manual

Radiator Thermostat Model M 

1st. English edition 12/2014 

Documentation © 2014 eQ-3 Ltd., Hong Kong. All rights reserved. 

Translation from original version in German.

CC-RT-M, V1.0, Art no. 141725

1. Information about this manual

Please read this manual completely and carefully before starting 

to use the device. The manual contains important information 

about the intended use of the device. Especially observe the 

safety notes. Keep the manual for later consultation. If you 

hand over the device to another person for use, please hand 

over the operating manual as well.

Symbols used:

Attention! 

This indicates a hazard.

Note. 

This section contains important additional information.

2. Package contents

1x   radiator thermostat

1x   adapter Danfoss RA

1x   adapter Danfoss RAV

1x   spigot extension Danfoss RAV

1x   adapter Danfoss RAVL 

1x   support ring

1x   nut M4

1x   cylinder head screw M4 x 12 mm

2x   1.5 V mignon/LR6/AA

2x   operating manual (English and German)

3. Operation and display

Mode  

Menu

A

B

C

D

E

H

G

F

A

  Bar chart of programmed heating phases

B

 ( ) Eco/comfort temperature, ( ) open-window function, 

(

Manu

) manual mode, (

Auto

) auto mode

C

 ( ) Holiday function, week day, (

) empty battery symbol

D

  Mode/Menu button: Switch between auto mode, manu mode 

and holiday function (press button briefly); open setup menu 

(press button for at least 3 seconds)

E

  Control wheel: Change settings, e.g. temperature / Menu 

choices (after pressing (

E

) (turn the control wheel)), activate 

the boost function and confirm/save settings in the menu 

(by pressing control wheel briefly)

F

  Union nut for fitting on the heating valve

G

  Display of temperature, time and date, menu options, 

functions

H

 

 button: Switch between eco and comfort temperature

4. Function

With the Radiator Thermostat Model M you can conveniently 

regulate the room temperature. Thanks to pre-programmed 

or individually tailored heating and non-heating phases the 

desired temperature can be comfortably adjusted. The device 

moves a valve to control the flow of heat to the radiator. The 

 

radiator thermostat fits to all common radiator valves and is 

easy to install without having to drain any water or intervene 

in the heating system. The additional boost function enables 

quick, short-term radiator heating by opening the valve for 5 

minutes. This immediately brings a comfortable warmth to the 

room.

5. Safety instructions

The device is not a toy; do not allow children to play with 

it.

Do not leave packaging material lying around, as it can 

be dangerous in the hands of a child.

Do not open the device: it does not contain any 

components that can be serviced by the user. In the event 

of failure, please return the device to our service 

department.

6. Disposal instructions

Do not dispose of the device with regular domestic 

waste.

Electronic devices must be disposed of in accordance 

with the Waste Electrical and Electronic Equipment 

Directive via local disposal points for electronic waste.

The CE sign is a free trading sign addressed exclusively 

to the authorities and does not include any warranty of 

any properties.

Used batteries should not be disposed of with 

regular domestic waste! Instead, take them to your 

local battery disposal point.

7. Inserting (replacing) batteries

Upon delivery, the batteries are already inserted with an 

insulation strip. For the device to function, please remove 

this strip. 

To replace the batteries, please proceed as follows:

• 

Press the battery compartment cover on both sides with 

your fingers and pull it away from device body.

• 

Insert 2 new LR6 (mignon/AA) batteries in the battery 

compartment, making sure they are the right way round.

• 

Reattach the battery compartment cover and latch it into 

place.

The service life of new alkaline batteries is approximately 

3 years. A battery symbol (

) on the display indicates 

that the batteries need to be replaced. After removing 

the empty batteries, wait approximately 1 minute before 

inserting the new ones. This device does not support 

operation with rechargeable batteries.

Never recharge standard batteries. Doing so will present 

a risk of explosion. Do not throw the batteries into a fire. 

Do not short-circuit batteries.

8. Set date and time

After inserting batteries, the date and time is automatically 

requested after a brief display of the firmware version number 

and short motor run ("INS").

• 

Set the year, month, day, hour and minute with the control 

wheel and confirm by pressing the control wheel briefly (

E

).

You can also adjust the time and date in the menu under 

"DAT".

The motor moves the control pin backwards during the setting 

of date and time.

• 

If "INS" and the rotating activity symbol " " are displayed, 

the motor is still reversing. When only "INS" is shown in the 

display, the radiator thermostat can be installed on the valve.

• 

The week program and other settings can be adjusted before 

installation. Press the Mode/Menu button for this, while "INS" 

is shown in the display. You will find further information in 

chapter "11. Setting week program".

• 

After the programming has been completed, "INS" is shown 

again in the display and installation can take place.

9. Installation on the radiator

The radiator thermostat is easy to install where thermostatic 

valves have previously been fitted, and can be done without 

draining heating water or intervening in the heating system. 

No special tools are required, and the heating does not have 

to be switched off. 

It is recommended to install the device while radiators / 

pipes are not hot.

The union nut attached to the radiator thermostat can be used 

universally and without accessories for valves of the most 

popular manufacturers with a thread size of M30 x 1.5 mm.

9.1 Removing the old dial

• 

Rotate your existing thermostat dial to the maximum value 

(anti-clockwise). The thermostat dial then no longer presses 

against the valve spindle, making it easier to remove.

• 

Now remove the thermostat dial. 

• 

If required, fix one of the supplied adapters. Afterwards, the 

adaption run can be initiated (see chapter „10. Adaption run“).

9.2 Adapters for Danfoss valves

By means of the adapters included in the package, the device 

can be installed on radiator valves of types Danfoss RA, RAV 

and RAVL. 

The assignment of the suitable adapter ring to the relevant 

valve can be found in the following illustrations.

The Danfoss valve bodies have elongated notches (

I

) around 

their circumference (see arrow), which also ensure that the 

adapter is properly seated when it snaps on.

If required, place the provided support ring (

L

) into the 

flange before installing the radiator thermostat.

During installation, please ensure that the pins inside the 

adapter (

J

) are lined up with the notches (

I

) on the valve. 

Ensure that the adapter is properly clipped on.

Take care during installation that you do not trap your 

fingers between the two halves of the adapter!

The RA and RAV adapters have been manufactured with pre-

tension in order to provide a better seat. Use a screwdriver 

during installation if necessary, and bend it open slightly in the 

vicinity of the screw. After clipping onto the valve body, please 

attach the adapter using the provided screw and nut. 

I

J

The spigot extension (

K

) must be fitted to the valve pin of RAV 

valves prior to installation. 

I

J

K

The adapter RAVL does not have to be screwed.

I

J

Support ring

The valves from different manufacturers may have tolerance 

fluctuations that make the radiator thermostat more loosely 

seated on the valve. In this case, the provided support ring (

L

should be placed into the flange before installing the radiator 

thermostat.

L

10. Adaption run

After the batteries have been inserted the motor reverses. 

Meanwhile, "INS" and the activity symbol ( ) are displayed.  

As soon as "INS" is displayed without the activity symbol  

( ), the radiator thermostat can be installed. This is followed 

by an adapting run ("AdA") to adapt the thermostat to the valve.

Reviews: