82
83
14.8 Setting offset temperature (tOF)
As the temperature is measured on the MAX! radiator ther-
, the temperature distribution can vary throughout
a room. To adjust this, a temperature offset of ±3.5°C can
be set. If a nominal temperature of e.g. 20°C is set at the
radiator but the room presents with only 18°C an offset of
-2.0°C needs to be set.
If you use the MAX! Radiator The in con-
nection with a MAX! Wall Thermostat, the tempera-
ture will be measured at the MAX! Wall Thermostat.
In the MAX! House Solution, all settings of the MAX!
Radiator The are made via the MAX! soft-
ware.
In the MAX! Room Solution, all settings of the MAX!
Radiator The are made via the MAX! Wall
The.
If you use the MAX! Radiator The in the
MAX! Radiator Solution, please proceed as follows:
•
Press the Auto/Menu button for more than 3 seconds.
•
Choose the menu item „tOF“ with the handwheel.
• Confirm with the Boost button.
•
Turn the handwheel and set the desired offset tempera-
ture (max. ±3.5°C).
• Confirm with the Boost button.
14.9 Teach-out of wireless components (UnL)
Devices that are taughed in to the MAX! Radiator Ther-
can be taughed-out. Thereby, all devices are un-
learned at once.
In the MAX! House Solution, all settings of the MAX!
Radiator The are made via the MAX! soft-
ware.
In the MAX! Room Solution, all settings of the MAX!
Radiator The are made via the MAX! Wall
The.
If you use the MAX! Radiator The in the
MAX! Radiator Solution, please proceed as follows:
•
Press the Auto/Menu button for more than 3 seconds.
•
Choose the menu item „UnL“ with the handwheel.
• Confirm with the Boost button.
• „ACC“ appears in the display. Confirm with the Boost
button to unlearn all taughed-in devices.
14.10 Resetting to factory status (rES)
The factory settings of the MAX! Radiator The can
be restored manually. All previous manual settings and in-
formation about taughed-in devices will be lost.
In the MAX! House Solution, all settings of the MAX!
Radiator The are made via the MAX! soft-
ware.