QX1000 Manual II: Administrator's Guide
Administrator’s Menus
QX1000; (SW Version 5.3.x)
109
Bad Supervisory Frame
shows the number of packets with an incorrect supervisory header.
Bad Unnumbered Information Frame
shows the number of packets with an incorrect unnumbered information frame header.
Bad Frame Type
shows the number of packets with a bad frame type.
Bad Unnumbered Frame
shows the number of packets with an incorrect unnumbered acknowledgement frame header.
Foreign TEI Value
shows the number of packets with a bad or foreign TEI (Terminal Endpoint Identifier) value.
ISDN BRI Layer 3
statistics:
Active Calls
shows the number of currently active calls in the selected trunk.
Outgoing Calls
shows the number of all outgoing calls in the selected trunk.
Incoming Calls
shows the number of all incoming calls in the selected trunk.
ISDN trunk statistics are not displayed on this page at first, but the page is automatically refreshed every 10 minutes. Statistics collected from that
time, as well as the last resetting of the counter, will be displayed there.
System Uptime
,
Current System Time
and
Last Time Cleared
(last time
ISDN statistics has been cleared) are displayed at the bottom of the page.
To reset the statistics counters press the
Clear
button.
External PSTN Gateways
The
External PSTN Gateways
page allows QX1000 to use the PSTN lines (FXO lines and/or ISDN trunks) on other QX1000s. This provides the
option to call not only through local PSTN lines but also through available shared FXO or ISDN lines in the network of QX1000s. When the sharing
mode is enabled and one QX1000 is configured to use the shared PSTN lines of another QX1000, the corresponding routing patterns will
automatically be created in the Call Routing Tables (see
) on both QX1000s. This will allow PSTN call routing between the two
QX1000s.
The
Use PSTN lines of the other device
checkbox is used to
enable QX1000 to use the shared PSTN lines on a remote
device. This selection requires you to configure the
Authorization Parameters. Use the same named link to access
the
Authorization Parameters
table.
Fig. II-185: External PSTN Gateways page
The
Authorization Parameters
page is used to create
accounts for the remote QX1000s allowing them to connect the
QX1000 and share the available PSTN lines. The table on this
page lists all registered accounts and account information. It will
show the corresponding authentication parameters (username
and password) and date/time of the last registration.
The
Add
functional button opens an
Add Entry
page where a
new account can be configured. A
Username
and a
Password
is required for a new account on this page.
Fig. II-186: External PSTN Gateways – Authorization Parameters page
To use the shared remote PSTN lines
1.
Enable the
Use PSTN lines of the other device
checkbox.
2.
Press
Save
to apply the selection.
3.
Enter the
Authorization Parameters
page.
4.
Create an account using a unique
Username
and a
Password
.