background image

Date : 

1. MOVEMENT DIMENSIONS

Outside diameter

φ

27.60mm (12H-6H) 

×

 24.00mm (3H-9H)

Casing diameter

φ

27.00mm (12H-6H)

Total height

3.7mm (including battery)

2. TIME STANDARD

Type of quartz oscillator

Tuning fork

Frequency of quartz oscillator

32,768 Hz

Accuracy

±

20 seconds per month (on wrist)

Operating temperature range

5

 to 

50

Regulation device

Nil (Pre-adjusted)

3. INDICATOR / FUNCTIONS

3 Hands

Hour / Minute / Second chronograph (Center)

Small hands

1/100 second chronograph / 1/10 second chronograph (12H)
40 minute chronograph (6H) / Small second (9H)

Calendar

Instant setting device for date calendar

Reset switch
System-reset switch
Power depletion warning function (BLD)

(Small second hand moves at 2-second intervals)

Chronograph

4. FEATURES

Jewels

0 Jewels

Anti-magnetism

Over 1600A/m (Direct current magnetic field)

Maximum unbalance of hands

Small second hand

: 0.03

μ

N

m

1/100 second chronograph hand

: 0.005

μ

N

m

1/10 second chronograph hand

: 0.025

μ

N

m

40 minute chronograph hand

: 0.03

μ

N

m

Second chronograph hand

: 0.06

μ

N

m

Minute hand

: 0.70

μ

N

m

Moment of Inertia 

Second chronograph hand

: less than 0.2

 μ

g

5. BATTERY 

Type / Size

Silver oxide battery /

φ

9.5mm 

×

 t 2.73mm

Recommended battery

SR927W 

Nominal voltage

1.55 V

Battery life

Approx. 3 years
(120 minutes chronograph operation per day)

Driving current consumption

Approx. 0.80

μ

A

Operation stopping voltage

0.9 V

6. SEPARATED PARTS (Parts code)

Hand setting stem

0351584 (Standard)  or  0351585 (Long)

Holding ring for dial

0866650 (Standard)  or  0866789 (Special)

Battery

SR927W 

Magnetic shield plate

4259519

A.C. comment seal

0110705

7. TEST OF ACCURACY

Equipment to be used

SEIKO quartz tester QT-99, QT2100
Greiner quartz timer-C , Witschi Q-tester 4000

Duration of measurement

10 seconds

Microphone to be used

Electromagnetic detection type

All specifications are subject to change without notice.

Cal.

Rev. :  01

30/Jan./'15

YM82A

Specifications

Analog Quartz 12''' Center second Chronograph Movement

The chronograph can measure up to 41 minutes in 1/100 second
increments, capable of timing 120 minutes.

P. 1 

Summary of Contents for YM82A

Page 1: ...Watch Movement Specification and Drawing CHRONOGRAPH Cal YM82A Movement Size Casing Diameter Height Battery Life 12 Ø 27 0mm 3 7mm 3 years ...

Page 2: ...ng 01 4 Hand setting stem 01 5 Magnetic shield plate 01 6 Dial 01 01 7 01 Dial 02 01 7 02 Holding ring for dial 01 02 8 01 Holding ring for dial 02 02 8 02 Attention for assembly 01 9 Attention of casing part structure 01 10 Attention of dial design 01 11 Operation 01 01 12 01 Operation 02 01 12 02 ...

Page 3: ...onograph hand 0 025μN m 40 minute chronograph hand 0 03μN m Second chronograph hand 0 06μN m Minute hand 0 70μN m Moment of Inertia Second chronograph hand less than 0 2 μg m 5 BATTERY Type Size Silver oxide battery φ9 5mm t 2 73mm Recommended battery SR927W Nominal voltage 1 55 V Battery life Approx 3 years 120 minutes chronograph operation per day Driving current consumption Approx 0 80μA Operat...

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ......

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ......

Page 13: ...tion of setting lever by tweezers Refer to the Fig 3 Each hand moves at step interval Set the each hand at correct position according to the scale on the dial in order not to make a mistake in reading time When installing or changing the battery it is recommended to remove three battery clamp screws first then remove the battery clamp not to damage the movement parts If you install the battery wit...

Page 14: ...er to the following picture not to install magnetic shield plate incorrect direction Cal YM82A Attention of casing part structure 30 Jan 15 Rev 01 When set and remove the hour hand repeatedly it may reduce the hand fixing torque because the hour wheel is made by plastic To ensure the enough fixing torque it isn t recommended to re assemble the hour hand more than five times Use the specified holdi...

Page 15: ...240 degrees from the start point The start position of the 40 minute chronograph hand can be set on the arbitrary positions in the range of 360 degrees Cal Attention of dial design 30 Jan 15 Rev 01 YM82A When the 40 minute chronograph hand set to 0 position the 40 minute chronograph hand turns a full round The dial index must be designed on the assumption that the 40 minute chronograph hand turns ...

Page 16: ...uttons at the same time for longer than 2 seconds It is necessary to set the 0 position after system reset 2 How to view the demonstration Crown position 0 click Reset the chronograph press 4H button for 3 seconds Press 2H button for 2 seconds here will allow you to resume the procedure again as indicated by the arrow if necessary 1 100 second chronograph and 1 10 second chronograph hands turns a ...

Page 17: ...increments capable of timing 120 minutes After the chronograph is started or restarted or split released the 1 100 second chronograph and 1 10 second chronograph hands move for 3 minutes and automatically stop at the 0 position counting continues inside 40 minute chronograph hand When the minute counting reaches 41 minutes the hand immediately returns and continues counting from 1 position and aga...

Reviews: