34
Connecting the Cash Drawer
Required specifications of cash drawers
Specifications of drawers differ depending on makers or models. When you use a drawer other than specified,
make sure its specification meets the following conditions.
Otherwise, devices may be damaged.
•
The load, such as a drawer kick solenoid, must be connected between pins 4 and 2 or pins 4 and 5 of the
drawer kick connector.
•
When the drawer open/close signal is used, a switch must be provided between drawer kick connector pins 3
and 6.
•
The resistance of the load, such as a drawer kick solenoid, must be 24
Ω
or more or the input current must be
1A or less.
•
Be sure to use the 24V power output on drawer kick connector pin 4 for driving the equipment.
Drawer Connection Diagram
Adaptable Connector
RJ12 modular connector
•
Do not connect both the optional external buzzer and the cash drawer to the printer at the
same time by using a branched connector.
•
When the optional external buzzer is enabled with the memory switch (customized values) (see
"Software Settings" on page 47
), a cash drawer cannot be used. Be sure to disable it when you
use a cash drawer.
•
Two driver transistors cannot be energized simultaneously.
•
Leave intervals longer than 4 times the drawer driving pulse when sending it continuously.
F.G
+24V
With shielded
Drawer kick connector
Printer side
User side
[Drawer kick side]
Drawer open/
close switch
Drawer kick
solenoid
1
2
3
4
5
6