EPSON Stylus Pro 9000
Disassembly & Assembly
59
TOP COVER REMOVAL
Preparation: Remove the Maintenance Cover. See
1.
Remove the four screws, CP(W2) M4x12, that secure the left-side lower
mounting bracket (spindle holder) and remove the bracket. Repeat for the
right-side lower mounting bracket.
Figure 4-4. Lower Mounting Bracket Removal
2.
Remove the four screws securing the Top Cover to the printer.
Figure 4-5. Top Cover Removal
3.
Lower the Paper Release Lever.
4.
Slide the Top Cover slightly forward to free it from its mounting brackets in
back. Then lift the Top Cover from the rear, tilting it forward, and lift it away
from the printer.
Mounting brackets
(lower)
C A U T I O N
When removing the Top Cover, avoiding catching its rear
edge on the Paper Thickness sensor, which may knock it
out of adjustment. The sensor’s approximate location is
shown in the figure above. You can also flex the back side
of the Top Cover slightly outward, toward the rear of the
printer, while removing the cover.
CP(W2) M3x6 screws
CP(W2) M4x6 screws
Paper Thickness Sensor