EPSON Stylus Pro 9000
Appendix
158
7.2.4 Electrical
The electrical specifications are for the 120 and 230 V units.
Rated voltage
120 to 140 VAC
Input voltage range
90 to 264 VAC
Rated frequency range
50 to 60 Hz
Input frequency range
49.5 to 61 Hz
Rated current
120 V: 0.5 A
230 V: 1.0 A (maximum 1.8 A)
Power consumption
Approximately 100 W (operating)
Approximately 30 W (standby)
(ISO/IEC 10561 letter pattern)
Energy Star compliant
Insulation resistance
10 M
Ω
minimum (between AC line
and chassis 500 VDC)
Dielectric strength
1500 V rms 1 minimum
(between AC line and chassis)
7.2.5 Environmental
Temperature
Operation
59 to 95 °F (15 to 35 °C)
Storage
–4 to 104 °F (–20 to 40 °C)
Transportation
–4 to 140 °F (–20 to 60 °C)
Humidity (without condensation)
Operation
30 to 80%
Storage
20 to 85%
Transportation
5 to 85%
Vibration resistance
Operation
0.15 G, 10 to 55Hz / X, Y, Z direction
Storage
0.50 G, 10 to 55Hz / X, Y, Z direction
Shock resistance
Operation
1 G, within 1 ms / X, Y, Z direction
Storage
2 G, within 2 ms / X, Y, Z direction
7.2.6 Ink Cartridge
Shape
Each ink cartridge is uniquely shaped so the cartridges cannot be
inserted into the wrong slots.
Ink colors
Black, cyan, magenta, yellow, light cyan, light magenta
NOTE:
Less than 1 month at 104 °F (40 °C); less than 120
hours at 140 °F (60 °C)
When storing the printer, make sure the printheads
are in the home, capped, position.
Before transporting the printer, remove the ink
cartridges and turn the ink valves screws to the
closed position. Also make sure the printheads are
in the home, capped, position. After transporting the
printer, install new ink cartridges.
When the temperature drops below 5
°F
(
–15 °C
)
, the
ink in the cartridges and printheads freezes. The ink
thaws completely after 3 hours at 77 °F (25 °C
)
.
Summary of Contents for Stylus Pro 9000 - Print Engine
Page 1: ...EPSONStylusPro9000 Wide Format Professional Inkjet Printer TM PRO9000 ...
Page 10: ... PRINTERBASICS ...
Page 21: ... TECHNICALOVERVIEW ...
Page 38: ... TROUBLESHOOTING ...
Page 54: ... DISASSEMBLY ASSEMBLY ...
Page 101: ... ADJUSTMENTS ...
Page 137: ... MAINTENANCE ...
Page 145: ... APPENDIX ...
Page 182: ...STYLUS PRO 9000 PM 9000C No 3 Rev 01 10052 PF Rail Assembly CAT 5003 201 202 ...
Page 197: ......
Page 198: ......