Mist Board Assy / Right side of the Main Frame
When routing the FFCs/cables on the Mist Board Assy and the FFC on right side of the Main Frame, follow the procedure below.
1. Before installing the Cable Holder Right to the Main Frame, route the Mist Board FFC through the groove and ribs (x3) of the Cable Holder Right.
2. Route the Mist Board FFC and Panel FFC along the reference line of the Main Frame in order, and secure them to the Main Frame with double-sided
tape.
3. Route the Mist Board FFC through the hole of the Main Frame.
4. Engage the section A of the Cable Holder Right to the Main Frame as shown above, and then secure the Cable Holder Right to the Main Frame with the
hooks (x2).
5. Route the Mist Board FFC along the reference line of the Mist Board Assy, and secure the Mist Board FFC to the Mist Board Assy with double-sided
tape.
6. Connect the Mist Board FFC to the Mist Board FFC connector.
Pull out the electrode cable from the cutout of the Main Frame and route the cable through the groove A and B as shown above, and then connect it to the
Mist Board.
Mist Board Cable Holder
Mist Board Cable Holder
Electrode cable
Cutout
Groove A
Groove B
Mist Board Assy
Double-sided tape
Reference line
Mist Board FFC connector
Double-sided tape
Reference line
Rib
Main Frame
Section A
Hook
Step 4
Mist Board FFC
Right side of Main Frame
Cable Holder Right
Mist Board FFC
Hole of Main Frame
Groove
Panel FFC
Step 1 to 3
Main Frame