2.3 Remedies for Service Call Error
The following tables explains the Service Call error messages and remedies.
Code
Error Name
Cause
Check Item
Remedy
1101
Ink Tubes life error
The Ink Tubes have reached the end of their service
life. (CR scan pass counter has reached a
predetermined limit.)
---
Replace the Ink Tubes
and reset the
counter
1125
CR HP detection error
The CR UNIT cannot set the home position.
False detection of the home due to foreign material
Misreading of the CR SCALE
CR Lock is damaged.
1. Is there any foreign material inside the printer?
2. Does the CR SCALE have any scratches or dirt?
3. Does the CR ENCODER SENSOR work properly?
Check it using the Service Program.
4. Does the CR Lock function normally?
1. Re-install the CR ENCODER SENSOR. If it is
faulty, replace it (CR UNIT).
2. Clean the CR SCALE using ethanol.
3. Replace the CR SCALE.
4. Replace the CR Lock (PUMP CAP ASSY).
1138
CR Motor
overcurrent error
1. Connection failure of the CR MOTOR ASSY or
the CR ENCODER SENSOR.
2. The number of occurrences of overcurrent to the
CR MOTOR ASSY has reached a predetermined
limit.
Irregular load
CR ENCODER SENSOR failure
CR MOTOR ASSY failure
1. Is there any problem such as disconnection or a
damaged cable in the connections below?
CR ENCODER SENSOR to CR SUB BOARD
CR MOTOR ASSY to SUB-B BOARD
2. Does the CR ENCODER SENSOR work properly?
Check it using the Service Program.
3. Is there any foreign material on the CR UNIT drive
path?
1. Replace the CR ENCODER SENSOR (CR
UNIT).
2. Replace the CR MOTOR ASSY.
113A
CR Motor
overload error
Overcurrent to the CR MOTOR ASSY was detected.
CR ENCODER SENSOR cable is damaged.
CR MOTOR ASSY cable is damaged.
Irregular load
CR ENCODER SENSOR failure
CR MOTOR ASSY failure
1. Is the CR UNIT being attached correctly?
2. Is there any foreign material on the CR UNIT drive
path?
3. Is there any problem such as disconnection or a
damaged cable in the connections below?
CR ENCODER SENSOR to CR SUB BOARD
CR MOTOR ASSY to SUB-B BOARD
4. Does the CR ENCODER SENSOR work properly?
Check it using the Service Program.
1. Re-install the CR UNIT.
2. Replace the CR ENCODER SENSOR (CR
UNIT).
3. Replace the CR MOTOR ASSY.
113B
CR Motor
over speed error
The CR MOTOR ASSY was driven at a speed faster
than a predetermined one during deceleration.
Irregular load
CR ENCODER SENSOR failure
SUB-B BOARD is damaged.
CR MOTOR ASSY driver failure
1. Are there any contamination or scratches on the CR
SCALE?
2. Does the CR ENCODER SENSOR work properly?
Check it using the Service Program.
1. Replace the CR ENCODER SENSOR (CR
UNIT).
2. Replace the SUB-B BOARD.
Summary of Contents for SC-F2000 Series
Page 1: ...SC F2000 Direct To Garment Printer SERVICE MANUAL SECP13002 Confidential ...
Page 10: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 29: ...Confidential C H A P T E R 2 TROUBLESHOOTING ...
Page 52: ...Confidential C H A P T E R 3 DISASSEMBLY ASSEMBLY ...
Page 192: ...Confidential C H A P T E R 4 ADJUSTMENT ...
Page 285: ...Confidential C H A P T E R 5 MAINTENANCE ...