ADJUSTMENT
CR Related Adjustments
108
Confidential
6. Move the CR Unit to the left end, and remove the CR Cover.
7. Loosen the screws that secure the PG adjustment levers on the left and the right.
8. Move the PG adjustment levers up and down to change the gap (PG).
9. Tighten the screws to secure the PG adjustment levers, and go back to
, and
repeat the procedure until the height of the CR Unit falls within the standard range.
Figure 4-5. PG Adjustment Levers
PG Adjustment Levers
Raise the lever to move the CR up
Lower the lever to move the CR down
Fixing screws