Maintenance 3. Covers
S5 Rev.5
94
3.5 Connector Plate
Remove the bolts, and then remove the Connector Plate.
Tool: Hexagonal wrench (width across flats: 3 mm)
Button head bolts: 8-M4×10 (with a washer)
Tightening torque: 1.4 N·m (0.14 kg·m)
For Cleanroom model
There is a gasket
(R13B031269)
between the cover and the
body.
Removal
Remove the gasket together with the cover.
Installation
Install the gasket between the cover and the body.
Do not reuse the gasket. Replace it with a new one.
For Protection model
Liquid gasket
(R13B031201) is applied.
Removal
Scrape off the old liquid gasket with a scraper or a similar tool.
Installation
Apply liquid gasket to the contacting face of the cover and the body.
Wipe off the excess gasket using a wiping cloth with alcohol.
NOTE
NOTE
Summary of Contents for ProSix S5 Series
Page 1: ...Rev 5 EM133R2483F EPSON ProSix S5 series MANIPULATOR MANUAL ...
Page 2: ...Manipulator manual S5 series Rev 5 ...
Page 10: ...viii S5 Rev 5 ...
Page 16: ......
Page 84: ...Setup Operation 5 Motion Range 70 S5 Rev 5 ...
Page 86: ...S5 Rev 5 72 ...