EPSON PhotoPC 3000Z
Revision A
Adjustment
Adjustment
77
ADJUSTMENT METHOD
1.
Set the siemens star chart 150 cm ± 3 cm so that it becomes center of the
screen.
2.
Double-click on the DscCalDi124.
3.
Click the “Focus”, and Click the “Yes”.
Figure 5-7. Lens Adjustment Button Location
4.
Adjustment value will appear on the screen.
Adjustment level
STD.AFOPS=0
Error: If STD.AFOPS is not “0”, it is an error.
Error example
STD.AFPOS=1: failure in detecting lens unit home position.
5.
Click the OK.
5.2.4 AWB Adjustment
PREPARATION
Power switch: ON
Dial switch: Communication mode
Figure 5-8. AWB Adjustment
ADJUSTMENT METHOD
1.
When setting the camera in place, set it to an angle so that nothing
appears in any part of the color viewer except the white section. (Do not
enter any light.)
2.
Double-click on the DscCalDi124.