4-15
EMP-822/EMP-83/EMP-X5/EMP-S5
SEIKO EPSON
Revision:A
4.3.4 Removing the Upper Case Unit
1. Remove the eight screws (C.B.P-TITE SCREW,3X10,F/ZB-3C) that secure the Upper Case
Unit from the bottom.
Figure 4-7.
2. Lift the Upper Case Unit carefully.
Figure 4-8.
Be careful, as there are 2 cables connected to the Upper Case Unit.
Upper Case Unit