4-47
EMP-822/EMP-83/EMP-X5/EMP-S5
SEIKO EPSON
Revision:A
4.5.2 Removing the PS Ballast Assy.
Removing the PS Ballast Assy.
1).Release the Ferrite Core and AC Inlet of the AC Cable from the Lower Case.
2).Remove the three screws (C.B.P-TITE SCREW,3X10,F/ZB-3C) that secure the PS Bal-
last Assy., and remove the PS Ballast Assy. from the Lower Case.
Figure 4-46.
This part is designated as the Safety Device. When removing/replacing the part
for repair, be sure to refer to the following section. According to the instructions
in it, handle the part and perform the procedure after servicing.
4.1.4 "Safety Check after Servicing" (p. 4)
PS Ballast Assy.
Ferrite Core
AC cable
Lower Case
AC Inlet
Safety Switch