3-15
REV.A
(Continued from the previous page)
Figure3- 18
2. Remove six fixing screws on the CD10MA board.
Screw: +M3*6 F/Ni: P/N1033122 (mounting torque: 4.5kg.cm = 3.9lb.inch)
3. Grasp the CD10MA board on the left side and disconnect the connector from the
CD10DR board.
Caution:
Never apply any mechanical stress to the CD10MA board to avoid malfunction caused
by wire breaking or solder flaking.
screw
screws
screws