Replacing Consumables
65
f
Resetting the lamp operating time
The projector records how long the lamp is turned on and a message and
indicator notify you when it is time to replace the lamp. After replacing
the lamp, make sure you reset the lamp hours from the configuration
menu.
Replacing the Air Filter
f
Air filter replacement period
It is time to replace the air filter when:
• The air filter has been turned brown by such things as tobacco
resin.
• When the message "The air filter is clogged. Clean or replace the
air filter." is frequently displayed, even though the air filter has
been cleaned.
f
How to replace the air filter
The air filter can be replaced even when the projector is suspended from a
ceiling.
A
After you turn off the projector's power and the
confirmation buzzer beeps twice, disconnect the
power cable.
B
Open the air filter cover.
While pushing the air filter cover catches, pull the cover down.
Attention
• Make sure you install the lamp securely. If the lamp cover is
removed, the lamp turns off automatically as a safety precaution.
If the lamp or the lamp cover is not installed correctly, the lamp
does not turn on.
• This product includes a lamp component that contains mercury
(Hg). Please consult your local regulations regarding disposal or
recycling. Do not dispose of it with normal household waste.
q
Only reset the lamp operating time after the lamp has been
replaced, otherwise the lamp replacement period is not
indicated correctly.
Procedure