EB-E01 series
Disassembly and Assembly
INTERNAL USE ONLY
SEIKO EPSON
135
Revision A
3.3.17 Filter Boards
DISASSEMBLY PROCEDURE
1. See
and remove all parts up to the component below from
the projector.
2. Remove the screw ( ) and remove the "Inlet Fasten Plate".
(This procedure is not applicable to EB-E01/X06/W06/E10/X51/W51/
W52)
3. Remove the screw ( ) and remove the "Inlet Cable".
4. Remove the screw ( ), release the hook ( ), and remove the "Filter
Board" and the "FB Insulation Sheet".
This part is designated as the Safety Device. When
removing/replacing the part for repair, be sure to refer to
3.5.1 Safety Check after Servicing (p142)
. After serving,
follow the procedures specified in the Safety Check after
Serving.
Inlet Fasten Plate
Inlet Cable
Filter Board
FB Insulation Sheet
Hook
C.P.(S-P1)SCREW,3X8.F/ZN-3C
C.P.(O)SCREW,4X6,F/NI
C.B.P-TITE SCREW,2.5X10,F/ZN-3C
Summary of Contents for EB-E01
Page 10: ...INTERNAL USE ONLY C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 23: ...EB E01 series Product Description INTERNAL USE ONLY SEIKO EPSON 23 Revision A EB W52 ...
Page 30: ...EB E01 series Product Description INTERNAL USE ONLY SEIKO EPSON 30 Revision A EB W52 ELPMB23 ...
Page 32: ...INTERNAL USE ONLY C H A P T E R 2 TROUBLESHOOTING ...
Page 63: ...INTERNAL USE ONLY C H A P T E R 3 DISASSEMBLYANDASSEMBLY ...