3.3.13 Lamp Fan (Assy)
DISASSEMBLY PROCEDURE
1. See
and remove all parts up to the component below from
the projector.
2. Remove the screw ( ), and pull the "Lamp Connector" out.
3. Remove the two screws ( ), and remove the “Lamp Fan (Assy)”.
Pass the Lamp Connector through the "Lamp Connector
Holder," and keep it pulled out until attaching. After
attaching the holder, fix it with a screw.
Route the "Lamp Fan" cable as shown in the figure below.
The cable should not be caught in the
exhaust duct
Lamp Connector
Lamp Fan (Assy)
C.B.P-TITE SCREW,2.5X10,F/ZN-3C
C.C.P-TITE SCREW,3X10,F/ZN-3C