Disassembly and Assembly
Removing the CR Motor
1. Remove the printhead. (See page 3-7.)
2.
Remove the printer mechanism.
(See Removing the Printer
on
page 3-26.)
3.
Remove the CP (PS) (M3 x 6) screw securing the timing belt holder and timing
belt.
Figure 3-54. Removing the Timing Belt Holder
4.
Disconnect the CR motor cable from the white, 2-pin connector on the
connector junction board assembly and unhook the CR motor cables at the
base frame
printer mechanism.
EPSON
Service Manual
3-49