EPSON AcuLaser C8500
Revision C
Disassembly/Assembly/Adjustment
Disassembly/Assembly Procedures
3-22
3.2.6.3 END GUIDE (PL2.1.16), SECTOR GEAR (PL2.1.18) Removal
1.
Remove the UNIVERSAL CASSETTE. (See Section 3.2.6.1.)
2.
Move the END GUIDE to the right end (= minimum paper size fits).
3.
Remove 2 screws (black, tapped, 8mm) securing the FRONT GUIDE
ASSY and remove the FRONT GUIDE ASSY.
4.
Push down the BOTTOM PLATE ASSY to lock it at the bottom.
5.
Turn the UNIVERSAL CASSETTE over and remove 5 screws (gold,
tapped, 8mm) securing the CASSETTE BOTTOM COVER. Then remove
the CASSETTE BOTTOM COVER.
Figure 3-18. END GUIDE, SECTOR GEAR Removal - 1
6.
Remove the SECTOR GEAR SPRING from the CASSETTE HOUSING
and SECTOR GEAR.
7.
Release the SECTOR GEAR from the swivel peg in the UNIVERSAL
CASSETTE, and slide the SECTOR GEAR along the groove to fit the
round end of the groove to the peg in the END GUIDE. Then remove the
SECTOR GEAR.
Figure 3-19. END GUIDE, SECTOR GEAR Removal - 2
Summary of Contents for AcuLaser C8500
Page 12: ......
Page 21: ...C H A P T E R 1 PRODUCTDESCRIPTIONS ...
Page 78: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 108: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 31 Figure 2 38 Xerographics II ...
Page 110: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 33 Figure 2 39 Development ...
Page 118: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 41 Figure 2 45 Drive ...
Page 120: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 43 Figure 2 46 Electrical ...
Page 153: ...C H A P T E R 3 DISASSEMBLY ASSEMBLY ADJUSTMENT ...
Page 269: ...C H A P T E R 4 DIAGNOSTICS ...
Page 353: ...C H A P T E R 5 TROUBLESHOOTING ...
Page 480: ...C H A P T E R 6 MAINTENANCE ...
Page 503: ...C H A P T E R 7 APPENDIX ...
Page 564: ......
Page 565: ......
Page 566: ......
Page 567: ......
Page 568: ......
Page 569: ......
Page 570: ......