AcuLaser C2800/C2800D/C3800/C3800D
Revision C
DISASSEMBLY/REASSEMBLY
Disassembly/Reassembly
369
Confidential
SENSOR PHOTO:CST NO PAPER
1.
Loosen the HARNESS ASSY C2 NO PAPER wrapped around the FEEDER ASSY UNIT OPT, and
pull the harness toward the SENSOR PHOTO:CST NO PAPER.
2.
Remove the screw (silver, 6 mm) that secures the HOLDER NO SNR to the FEEDER ASSY UNIT
OPT, and remove the HOLDER NO SNR.
3.
Release the three tabs that secure SENSOR PHOTO:CST NO PAPER to the HOLDER NO SNR,
and remove the SENSOR PHOTO:CST NO PAPER.
4.
Disconnect the connector (P/J42121) of the SENSOR PHOTO:CST NO PAPER.
B
Kmy03244E
B
1)-1
1)-2
3)
2)
4) (J42121)
SENSOR PHOTO:CST NO PAPER
ACTUATOR NO PAPER A4
1.
While holding down the circular tab that secures the HOLDER NO PAPER L A4 to the SUPPORT
NUDGER ASSY, disengage the three tabs, and remove the HOLDER NO PAPER L A4 by sliding it
sideways.
The stopper of the ACTUATOR NO PAPER A4 should be placed underneath the
HOLDER NO PAPER L A4.
2.
Pull out the shaft of the ACTUATOR NO PAPER A4 from the hole of the HOLDER NO PAPER R
A4, and remove the ACTUATOR NO PAPER A4.
C
Kmy03245EA
2)
1)-1
1)-2
HOLDER NO
PAPER L A4
ACTUATOR
NO PAPER A4
Stopper
Tab
ACTUATOR NO PAPER A4
Summary of Contents for AcuLaser C2800D
Page 13: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 30: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 76: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 159: ...Confidential C H A P T E R 4 DISASSEMBLY REASSEMBLY ...
Page 381: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Page 389: ...Confidential C H A P T E R 6 MAINTENANCE ...