AcuLaser C2800/C2800D/C3800/C3800D
Revision C
DISASSEMBLY/REASSEMBLY
Disassembly/Reassembly
361
Confidential
COVER RIGHT
1.
Remove the four screws (silver, brimmed, 8 mm) that secure the COVER RIGHT to the FRAME
ASSY OPT.
2.
Pull the protrusion of the COVER RIGHT out of the concave surface of the FRAME ASSY OPT,
and remove the COVER RIGHT.
A
Kmy03235EA
1)
1)
1)
1)
2)
COVER RIGHT
SWITCH ASSY SIZE
1.
Disconnect the connector (P/J4211) that is connected to the SWITCH ASSY SIZE.
2.
Remove the clamp, which is connected to the SWITCH ASSY SIZE, together with the harness.
3.
Remove the screw (silver, self-tapping, 8 mm) that secures the SWITCH ASSY SIZE to the GUIDE
TRAY R 550.
4.
Pull out the guide pin on the bottom of the SWITCH ASSY SIZE from the square holes on the
GUIDE TRAY R 550, pull out the two guide pins from the hole on the GUIDE TRAY R 550, and
remove the SWITCH ASSY SIZE.
A
Kmy03236EA
2)
3)
4)
1) (J4211)
SWITCH ASSY SIZE