AcuLaser C2800/C2800D/C3800/C3800D
Revision C
TROUBLESHOOTING
Print Quality Trouble FIP
146
Confidential
FIP-P10 "GHOST IMAGES" APPEAR ON THE PRINTED PAGE
Before starting troubleshooting, inspect the paper feed path of the printer paper. Check
the paper feed path for metal staples, paper clips, paper scraps, and other foreign
matter.
Symptom / Possible Parts
Symptom
An image of the previous page or part of the currently
printing page laps over.
Possible Parts
TRANSFER UNIT
PWBA MCU
BOARD ASSY, MAIN
HVPS
Step
Check
Yes
No
1
Check of repeated printing
Did the symptom occur after printing same
image in large quantities?
Go to Step [2].
Go to Step [3].
2
Check the residual image
Print out 10 pages of various images.
Did any residual images appear?
Go to Step [3].
End of procedure
(Advise the
customer not to
print same image
in large quantities
at a time.)
3
Check the belt surface of the TRANSFER
UNIT
Is the belt surface damaged?
Replace the
TRANSFER
UNIT.
Go to Step [4].
4
Check the cycle of the rollers
If the residual images appear at regular
intervals, does the interval match the cycle of
any rollers? (Refer to the table in
.)
Replace the
possible parts one
by one.
Go to Step [5].
6
Check after replacing the PWBA MCU
Replace the PWBA MCU
and make a
test print. Are images printed normally?
End of procedure Replace the
BOARD ASSY,
MAIN.
Step
Check
Yes
No
Summary of Contents for AcuLaser C2800D
Page 13: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 30: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 76: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 159: ...Confidential C H A P T E R 4 DISASSEMBLY REASSEMBLY ...
Page 381: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Page 389: ...Confidential C H A P T E R 6 MAINTENANCE ...