4. Slowly insert the photoconductor unit vertically, and then push it slightly down toward you to
finish reinstalling the photoconductor unit.
5. Carefully close the top cover.
Cleaning the Print Head Window
1. Use either operation described below to switch the printer to Print Head Cleanup mode.
❏
Hold down the Rotate Toner key for 5 to 9 seconds.
❏
On the Panel tab of the Remote Panel Program, click the
P/H Clean Up
button.
Note:
❏
The printer enters Print Head Cleanup mode, and the magenta toner indicator lights up.
❏
It is not possible to exit Print Head Cleanup mode before the operation is finished (even if the
Clear key is pressed).
If the printer has incorrectly been switched to Print Head Cleanup mode, perform steps 2 through
4, then steps 10 through 14 (skipping steps 5 through 9) to exit Print Head Cleanup mode.
AcuLaser C1600 User’s Guide
Maintenance
57