Note:
To replace the toner cartridge for another color, after the front cover has been closed, check that the
indicator for the toner to be replaced is lit (if necessary, press the Rotate Toner key), and then replace
the toner cartridge as described in steps 2 through 10.
11. Press the Clear key to reset the printer and clear the indicator message.
Note:
The printer must complete a calibration cycle after a toner cartridge has been replaced. If you open
the top or front cover before the printer is reset, the calibration stops, then starts over again after the
cover is closed.
Removing All Toner Cartridges
Note:
Be careful not to spill toner while replacing a toner cartridge. If toner spills, immediately wipe it off with a
soft, dry cloth.
By using the Eject All Toner mode, all toner cartridges can be removed.
Follow the procedure described below to use the Eject All Toner mode.
1. Use either operation described below to switch the printer to Eject All Toner mode.
❏
Hold down the Rotate Toner key for more than 10 seconds.
❏
On the Panel tab of the Remote Panel Program, select
Eject All Toner
, and then click the
Rotate Toner
button.
Note:
❏
The printer enters Eject All Toner mode, and the magenta toner indicator lights up.
❏
To exit Eject All Toner mode, press the Clear key.
AcuLaser C1600 User’s Guide
Replacing Consumables
45