Specifications
Initialization Methods
SCSI interface
Hardware: Initialized when the scanner
is turned on or the scanner
receives a SCSI Reset signal
from the SCSI interface
Software:
Initialized when the
software sends the Esc @
(initialize the scanner
command), or the scanner
receives a SCSI Bus Device
message
USB interface
Hardware: Initialized when the scanner
is turned on or the USB
cable is plugged into the
USB port on the scanner
Software:
Initialized when the
software sends the Esc @
command or the scanner
receives a Bus Reset from
the USB interface
Automatic Document
Feeder (B813212)
General
Paper input/output
Load face up; eject face down
Paper quantity
100 pages (55 g/m
2
paper,
maximum total thickness
under 0.48 inches [12 mm])
Reliability
100,000 sheets (load/eject MCBF)
Dimensions
Width:
23.8 inches (605 mm)
Depth:
19.2 inches (488 mm)
Height:
5.3 inches (134 mm)
Weight
Approximately 28.7 lb (13 kg)
Electrical
Input voltage
22.8 to 25.2 VDC
4.75 to 5.25 VDC
Input current
24 V: 1.5 A
5 V:
0.4 A