E0C88832/88862 TECHNICAL MANUAL
EPSON
133
7 ELECTRICAL CHARACTERISTICS
V
DD
RESET
t
psr
Vsr
0.5V
DD
0.1V
DD
Power ON
*1 When the built-in pull up resistor is not used.
*2 Because the potential of the RESET terminal not reached V
DD
level or higher.
V
DD
RESET
V
SS
*2
*1
■
Power ON reset
■
Operating mode switching
RESET
t
sr
V
IL
V
IH
•
RESET input clock (All operating mode)
Symbol
Min.
Typ.
Max.
Unit
RESET input time
t
sr
µ
S
Note
100
Item
Condition: V
DD
= 1.8 to 5.5 V, V
SS
= 0 V, Ta = -40 to 85
°
C, V
IH
= 0.5V
DD,
V
IL
= 0.1V
DD
Symbol
Min.
Typ.
Max.
Unit
Operating power voltage
RESET input time
Vsr
t
psr
V
mS
Note
2.4
10
Item
Condition: V
SS
= 0 V, Ta = -40 to 85
°
C
Symbol
Min.
Typ.
Max.
Unit
Stabilization time
t
vdc
mS
Note
1
5
Item
Condition: V
DD
= 1.8 to 5.5 V, V
SS
= 0 V, Ta = -40 to 85
°
C
Note) 1
Stabilization time is the time from switching on the operating mode until operating mode is stabilized. For example,
when turning the OSC3 oscillation circuit on, stabilization time is needed after the operating mode is switched on.