PS 9000 1U Series
1.9.4 The control panel (HMI)
The HMI (
H
uman
M
achine
I
nterface) consists of a display, two rotary knobs with pushbutton function and six
pushbuttons.
1.9.4.1 Display
The graphic display is divided into a number of areas. In normal operation the left upper half is used to show actual
values and the lower half is used to display status information and set values:
Actual values
U/I or U/P
Regulation mode
Alarms
Set value of voltage
Status: control location / panel lock
Set value of current or
Set value of power
•
Actual values area (upper half)
In normal operation the DC output values (large numbers) of voltage and current resp. of power are displayed,
depending on the selected view mode. The display format of values is according to what’s listed in
Furthermore, the actual regulation mode
CV, CC
or
CP
) is displayed here, as well as
alarms with abbreviations (
OT, OVP, OCP, PF, OPP
). For details refer to
.
•
Set values area (lower half, left and right side)
The set values of voltage and current (mode: U/I) resp. of voltage and power (mode: U/P) are displayed here and
are adjustable with the left hand and right hand rotary knobs when operating the device manually. While doing
so, the digit to adjust can be selected by pushing the corresponding rotary knob, in order to move the cursor. The
left hand rotary knob is always assigned to the DC output voltage and related parameters like OVP or U-max,
whereas the right hand rotary knobs is either assigned to the DC output current and related parameters or to the
DC output power. In remote control condition, no matter if analog or digital, the set values given from remote are
displayed here.
Logically, the values are increased by clockwise turning and decreased by anti-clockwise turning, unless they are
somehow limited by a maximum value or an adjustment limit (see
).
General display and settings ranges:
Display
Unit
Range
Description
Actual voltage
V
0-125% U
Nom
Actual values of DC output voltage
Set value voltage
V
0-102% U
Nom
Set value for limiting the DC output voltage
Actual current
A
0.2-125% I
Nom
Actual value of DC output current
Set value current
A
0-102% I
Nom
Set value for limiting the DC output current
Actual power
W
0-125% P
Nom
Actual value of output power, P = U * I
Set value power
W
0-102% P
Nom
Set value for limiting DC output power
Adjustment limits
A, V, kW 0-102% Nominal val. U-max, I-min etc., related to the physical units
Protection settings A, V, kW 0-110% Nominal val. OVP, OCP etc., related to the physical units
•
Status area (lower half, middle)
This area shows the control location mode (see
) or another status (see table below). In
case pushbutton
is activated while the output is on, the quick menu (see
) will be
displayed: