Chapter 4: Meter Memory, Setup 

Memory, Storing Test Results 

Your meter stores a maximum of 480 test results with the time and date of the test. You can review them at 
any time. When the memory is full, the oldest result is dropped as the newest is added, so it is very important 
to have the correct time and date set in the meter.   
 
 
 

Note: 

1.  Do not change your therapy based on one individual result in memory. 
2.  The memory is not lost when you replace the battery. You do need to check that the time and 

date are still correct. See the section "Setting the time and date" in Chapter 1. 

3.  Once 480 results are in memory, adding a new result causes the oldest one to be deleted. 

Summary of Contents for EasyPlus mini R2N

Page 1: ......

Page 2: ...EasyPlus mini R2N Self Monitoring Blood Glucose System User s Manual Please read this User s Manual thoroughly before using your blood glucose meter...

Page 3: ...e the EasyPlus mini R2N Self Monitoring Blood Glucose System To start testing quickly you can also refer to the Quick Reference Guide Thanks again for choosing the EasyPlus mini R2N SMBG Intended Use...

Page 4: ...anual Self Test Log Book Warranty Card EasyPlus mini R2N Blood Glucose Meter Test Strip Instructions Lancing device EasyPlus mini R2N Blood Glucose Test Strips 10 pcs Glucose Control Solution Instruct...

Page 5: ...Customer Care Service toll free at 1 866 203 2761 Eastern Time Mon Fri 9 00AM 5 00PM You can also visit www epsbio com tw for diabetes management tools and product demonstrations Please complete your...

Page 6: ...disassemble the meter as this may cause damage to the components resulting in incorrect readings Disassembling the meter will also void the warranty Always keep the meter clean and store it in a safe...

Page 7: ...lood even after cleaning should be handled as if capable of transmitting a viral disease Consult with your healthcare professional before testing on your forearm Do not touch the strips with wet hands...

Page 8: ...followed the steps in the user s manual but still have symptoms that don t seem to match your test results or if you have questions please talk to your doctor or health care professional Please read...

Page 9: ...Run A Control Solution Test 16 About The Control Solutions 17 Running A Control Solution Test 18 Understanding Control Test Results 20 Chapter 3 Testing Your Blood Glucose 22 Using The Lancing Device...

Page 10: ...lts 34 Viewing Test Results 35 Setting The Alarm 36 Chapter 5 Maintenance And Troubleshooting 37 Installing Batteries 37 Cleaning Your Meter 38 Maintenance And Testing 39 Cleaning Your Lancing Device...

Page 11: ...t be included in the testing memory G Hypo Set your hypo value When test result is under the setting value meter will alarm you H Hype Set your hype value When test result is over the setting value me...

Page 12: ...r A Anti Slippery Ring B Battery cover C Display D Manufacturer information E Serial number F Strip slot The Overview of the Test Strip A Blood collection area B Reaction area C Holding area D Strip i...

Page 13: ...memory 1 Press W until turning the meter on Press W once again and release to enter the setting mode 2 The last 2 digits of the year flash at the center of the display Press X to adjust the year and P...

Page 14: ...to confirm the setting 5 Press X to adjust value of hype and Press W to confirm the setting 6 When setting is finished the display will be back to the testing mode of flashing strip Note Hypo setting...

Page 15: ...control solution or the accuracy of the system as a whole 1 Make sure your check strip is inserted The meter will turn on automatically 2 The screen displays OK 3 Remove the check strip and the meter...

Page 16: ...reuse it Record the date you open the test strip bottle Be sure to check the expiration date on the test strip bottle The test strip is good for three months from the date the bottle is opened or unti...

Page 17: ...results You should run the control solution tests when You use the EasyPlus mini R2N Blood Glucose Meter for the first time You open a new bottle of test strips You think the meter or test strips may...

Page 18: ...t are past the expiration date The control solutions can stain clothing If you spill them wash your clothes with soap and water Close the bottle tightly after every use Left over control solutions sho...

Page 19: ...queeze the bottle until a tiny drop forms at the tip of the bottle Touch the drop to the Blood collection area at the end of the test strip Do not put control solution on top of the test strip When yo...

Page 20: ...be inside this range Make sure you compare the result to the correct level of control 6 A result appears on the display Don t remove the test strip yet Check if the reading falls within the range pri...

Page 21: ...ips and your meter is working properly If your control result is not inside the acceptable range printed on your test strip bottle here are some things you can do to solve the problem Note Control Sol...

Page 22: ...s functions 9 Are the control solutions expired or contaminated Replace with a new control solution to check the performance of SMBG system 9 Were test strips and control solutions stored in cool dry...

Page 23: ...t for you Please do not share your lancing device with anyone And always use a new sterile lancet Lancets are for one time use only Note Used test strips and lancets are considered bio hazardous waste...

Page 24: ...The Lancing Device You must first load the lancet into the lancing device to get it ready for use 1 Take the cap off 2 Insert the lancet into the lancing device firmly then twist off the protective c...

Page 25: ...for average and 6 8 for thick or calloused skin 6 Set the lancing device aside until later in the test 5 Pull on the sliding barrel of the lancing device until it clicks and then release Now the lanci...

Page 26: ...e meter turns on 3 Swab the blood collection area on your finger with an alcohol swab Please wait at least 5 seconds until the intended area is dry and clean before sampling the blood 4 Place the lanc...

Page 27: ...ip Do not put blood on top of the strip Be sure to get enough blood on the strip s reaction zone Otherwise an inaccurate reading may result 7 The meter will beep when enough blood has entered the stri...

Page 28: ...meal or fasting state more than 2 hours since the last meal Two hours or more after taking insulin Two hours or more after exercise Do NOT use AST if you think your blood glucose is low you are unawar...

Page 29: ...atch how you feel do a fingertip test to confirm the result again Do NOT change your treatment just because of an alternate site result do a fingertip test to confirm the result If you often do not no...

Page 30: ...AST testing 3 Press and hold the device with one clear adjustable tip against the forearm 4 Press the trigger button to activate the lancing device Hold the device against forearm and increase pressur...

Page 31: ...stable cap off Without touching the used lancet stick the lancet tip into its protective cover Grip the lancet carrier firmly and pull the lancet safely out 2 Discard the used disposable lancet into a...

Page 32: ...l Test Results If your test result doesn t match the way you feel please follow these steps 1 Run a control test Chapter 2 Control Solution Testing 2 Repeat a blood glucose test Chapter 3 Testing Your...

Page 33: ...ater than 240 mg dL and you have symptoms of high blood glucose contact your healthcare professional instantly If the result does not match how you feel follow the steps under Unusual Test Results Wha...

Page 34: ...ically not a problem with your meter it just means that time has elapsed and your blood glucose has changed If you want to compare your meter result to the lab result you must be fasting Bring your me...

Page 35: ...the newest is added so it is very important to have the correct time and date set in the meter Note 1 Do not change your therapy based on one individual result in memory 2 The memory is not lost when...

Page 36: ...Press W to view the previous results in order from the latest to the earliest 3 Press X once again to view averages of 7 day test result 4 Press W to review averages of 14 day 30 day and 90 day test r...

Page 37: ...of alarm 2 Press W to set On for the first alarm 3 Press W to adjust time and press X to confirm the setting 24 hour clock 4 Press X to confirm the first setting and then get into the second one 5 Re...

Page 38: ...teries when you first use the meter or replace with new batteries when the LP message and the low battery symbol appear on the display Note 1 The meter won t delete earlier records after you replace b...

Page 39: ...ater stains Follow these guidelines carefully to help you get the best performance possible Do Not Get any moisture in the test strip slot Spray any cleaning solution directly onto the meter Put the m...

Page 40: ...see the complete display All the indicators should be clear and look exactly like the picture to the left If not call the Customer Care Service Center toll free 1 866 203 2761 Eastern Time Mon Fri 9 0...

Page 41: ...Time Mon Fri 9 00AM 5 00PM System fault Action Replace the batteries first If 001 ERROR appears again please call Customer Service toll free 1 866 203 2761 System fault Action Replace the batteries f...

Page 42: ...pears Temperature is too low outside the required range of 50 F 104 F 10 C 40 C This alerts users that an incorrect result may occur if the test continues Action Relocate the meter to a location with...

Page 43: ...Temp 50 F 104 F 10 C 40 C Operating condition Relative Humidity R H 90 0 6 L Blood sample Fresh blood from fingertip or forearm Hematocrit Hct 20 60 Power CR2032 Lithium Cell 3V 2 pcs Battery life Ove...

Page 44: ...it above 60 may cause lower results If you do not know your hematocrit level please consult with your healthcare professional 6 Altitude up to 10000 feet above sea level has no effect on readings Heal...

Page 45: ...cally ill patients should not be tested with home use blood glucose meters 11 Interfering Substances depend on the concentration The below substances up to the test concentration will not affect the t...

Page 46: ...Care 25 2002 p S37 Manufacturer EPS BIO TECHNOLOGY CORP 2F No 49 2 Lane 2 Guang Fu Rd Sec 2 Hsinchu City Taiwan 300 TEL 886 3 5752522 FAX 886 3 5752552 E mail info epsbio com tw Website http www epsb...

Page 47: ...ets the requirements of MDD 93 42 EEC Manufacturer SAE HAN MEDICAL CORP 700 113 PUB GOT DONG IL SAN GU GOYANG CITY KYUNGGI DO KOREA TEL 82 31 923 4330 FAX 82 31 923 4331 E mail saehan saehanmed com Re...

Reviews: