Safety and operating instructions
© Construction Tools PC AB | 9800 1273 01 | 2020-04-03
Original Instructions
13
4 Transport
WARNING
Falling hydraulic breaker
If the hydraulic breaker is tipping over and falling, it may
cause serious injury.
u
Place the hydraulic breaker in a safe position where
it cannot fall over and cause damage.
NOTICE
Air freight restrictions
HATCON contains an activated SIM card (radio transmit-
ting device) and an encased lithium ion battery after acti-
vation step has been finalized. Both parts are regulated
for air transport.
u
Consult your forwarder or local customer center/
dealer about any restrictions for air freight.
4.1 Lifting the hydraulic breaker
Carefully check that the carrier is stable enough when
transporting, performing maintenance, or other kinds of
work with the hydraulic breaker.
The hydraulic breaker is delivered in a box. To lift the hy-
draulic breaker in a safe way, fit the lifting strap in the
manner shown in the illustration below.
4.2 Transport using a forklift
When using a forklift. Place the hydraulic breaker at a
pallet. Use wedges and strapping to secure it. Slowly lift
and transport the hydraulic breaker to its intended desti-
nation.
4.3 Transport using a lorry
Put the hydraulic breaker on an anti-slip mat at the lorry.
Secure the machine to the loading surface with straps.
Observe all the applicable national and regional regula-
tions on securing loads.
5 Installation
Before installing the hydraulic breaker on the carrier or
operating it, read the operation manual and safety in-
structions provided by the carrier manufacturer. Follow
all instructions.
The carrier must have the appropriate hydraulic system
for operation of the breaker.
If the carrier is too large for the hydraulic breaker it may
lead to broken working tools and increased wear. See
"Technical data" for choosing suitable carrier.
The safety equipment in the hydraulic system must be
checked for quality (CE mark, etc.), suitability and func-
tionability by a professional or authorised supervisor be-
fore use.
5.1 Hoses and connections
WARNING
Whipping hydraulic hose
Hydraulic hoses under pressure can whip uncontrollably
if screws loosen or are loosened. A whipping hydraulic
hose can cause severe injuries.
u
Depressurize the hydraulic system before loosening
the connection of a hydraulic hose.
u
Tighten the nuts on the connections of the hydraulic
hoses to the required torque.
Type of nipple: ORFS standard nipple. The nipple di-
mensions can be found in the Spare parts list.
The quality of the hydraulic hoses must be 2SC (accord-
ing to EN 857) or better when connecting the breaker to
the carrier. If quick couplings are to be used, we recom-
mend using the 'Flat Face' quick coupling. This type is
sturdy and easy to clean. The quick coupling pressure
class must agree with the carrier's working pressure.
Always clean the quick couplings before mounting or dis-
mounting. Always plug hoses and hose nipples with tight
and clean end caps when dismounting.
Hose connections
Right (As seen from operator’s seat)
Air flushing
Central lu-
brication
Tank, re-
turn line
Symbol
SB 702
G ½ in.
G ¼ in.
G 1 in.
SB 1102
G ½ in.
G ¼ in.
G 1 in.
Summary of Contents for SB 1102