Networked VGA Grid User
Guide
Control with RS-232 / serial port
Label
Description / Options
when your control terminal requires it (see control terminal manual).
None
No flow control is used. Only select this if your control terminal requires it (see control
terminal manual).
4. Click
Apply
.
Control the Networked VGA Grid with RS-232
You can use the null-modem cable and your control terminal software to issue commands to the Networked
VGA Grid such as when to start or stop recording, or to retrieve or set the value for various settings.
Each command sent to the Networked VGA Grid via RS 232 must be terminated with a line feed
(LF) character (ASCII code 10). Your software may need to be configured to add the line feed to
each command.
Some commands require a
channel
or
recorder
name as an argument. In those commands, the channel or
recorder name is separated from the command name by a period, as shown in the table. The channel name
value can be either the name or the index of the recorder or channel. Use of the index is recommended.
A channel's index is found by looking at the Channels list in the Admin panel. In the screen capture below, the
channel with index 1 is currently recording (it's index number is red). To address this channel via RS-232
commands, use the index 1.
For commands requiring a recorder index, determine your recorder's index by combining the recorder's
number with the prefix m. In the example below, the second recorder's index is 2. To access this recorder via
RS-232 commands, use the index m2.
342