39
/
Load and fault icon blink
(night time>3 hours).
Load Short
Circuit
①
Check carefully loads
connection, clear the fault.
②
Restart the controller.
③
Wait for one night-day cycle
(night time>3 hours).
5.3 Maintenance
The following inspections and maintenance tasks are recommended at least two times per year for
best performance.
Make sure controller firmly installed in a clean and dry ambient.
Make sure no block on air-flow around the controller. Clear up any dirt and fragments on
heat sink.
Check all the naked wires to make sure insulation is not damaged for sun exposure,
frictional wear, dryness, insects or rats etc. Repair or replace some wires if necessary.
Tighten all the terminals. Inspect for loose, broken, or burnt wire connections.
Check and confirm that LED is consistent with required. Pay attention to any
troubleshooting or error indication .Take corrective action if necessary.
Confirm that all the system components are ground connected tightly and correctly.
Confirm that all the terminals have no corrosion, insulation damaged, high temperature or
burnt/discolored sign, tighten terminal screws to the suggested torque.
Clear up dirt, nesting insects and corrosion in time.
Check and confirm that lightning arrester is in good condition. Replace a new one in time to
avoid damaging of the controller and even other equipment.
WARNING
Risk of electric shock!
Make sure that all the power is turned off before above operations, and then
follow the corresponding inspections and operations.