56
3.6 Battery voltage customized logic.
For the above items7-16 and 33-36, please follow the below rules strictly.
1) The following rules must be followed when modifying the parameter values
in the user for a Lead-acid battery.
A. Over Voltage Disconnect Voltage
≥ Over Voltage Reconnect 1V
B.
Over Voltage Disconnect Voltage > Charging Limit Voltage ≥ Equalize Charging
Voltage ≥ Boost Charging Voltage ≥ Float Charging Voltage > Boost Reconnect
Charging Voltage.
C. Low Voltage Reconnect Voltage
≥ Low Voltage Disconnect 1V
D.
Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage ≥ Discharging
Limit Voltage(42.4V).
E. Under Voltage Warning Reconnect Voltage-1V
≥ Under Voltage Warning Voltage
≥ Discharging Limit Voltage(42.4V).
F. Boost Reconnect Charging voltage > Low Voltage Disconnect Voltage.
2) The following rules must be followed when modifying the parameter values
in the user for a lithium battery.
A. Over Voltage Disconnect Voltage
≥ Over Voltage Reconnect 1V
B. Over Voltage Disconnect Voltage>Over Voltage Reconnect Voltage
=
Charging
Limit Voltage ≥ Equalize Charging Voltage
=
Boost Charging Voltage ≥ Float
Charging Voltage>Boost Reconnect Charging Voltage;
C. Low Voltage Reconnect Voltage
≥ Low Voltage Disconnect 1V
D.
Low Voltage Reconnect Voltage>Low Voltage Disconnect Voltage ≥ Discharging
Limit Voltage(42.4V);
E. Under Voltage Warning Reconnect Voltage-1V
≥Under Voltage Warning Voltage≥
Discharging Limit Voltage(42.4V);
F. Boost Reconnect Charging Voltage> Low Voltage Reconnect Voltage;
The lithium battery's voltage parameters must be set according to the voltage
parameters of BMS.
Summary of Contents for UP2000-HM6022
Page 2: ......
Page 4: ...6 Maintenance 63 7 Specifications 64 Appendix 1 Disclaimers 73...
Page 11: ...7 1 2 Identification of parts...
Page 15: ...11 1 4 Connection diagram No battery mode Battery mode...
Page 78: ......
Page 79: ......