Epever LS1024BPD Quick Start Manual Download Page 1

                                                   

    BEIJING EPSOLAR TECHNOLOGY CO., LTD.                          Tel

+86-10-82894112 / 82894962        Website

www.epsolarpv.com/www.epever.com 

                                                          1                                                                                                                          2   

LS BPD series Solar Charge Controller 

1. Safety Information 

  Read all of the instructions in the manual before installation. 

  DO NOT disassemble or attempt to repair the controller. 

  Install external fuse or breaker as required. 

  Do disconnect the solar module and fuse/ breakers near to battery before installing or 

moving the controller. 

  Power connections must remain tight to avoid excessive heating from a loose 

connection. 

  Only charge batteries that comply with the parameters of controller. 

  Battery connection may be wired to one battery or a bank of batteries. 

  Risk of electric shock, the PV and load can produce high voltages when the controller is 

working. 

2. Overview 

Thank you for selecting the LS BPD series solar charge controller. The LS-BPD controller 
is a waterproof PWM charge controller that adopts the most advanced digital technique.

 

The multiple load control modes enable it can be widely used on solar home system, field 
monitoring, traffic signal, solar street light, solar garden lamp, etc.   

 

It

’s an easy operation and cost efficient controller featured as:  

  3-Stage intelligent PWM charging

Bulk, Boost/Equalize, Float 

  Support 3 charging options: Sealed, Gel, and Flooded. 

  Programmable LVD and main parameters via digital tube and button   

  Multiple load control modes   

  Extensive Electronic protection 

  Battery temperature compensation function. 

 

IP67 waterproof degree 

3. Product Features 

 

 

 

 

 

 

 

 

① 

Mounting hole

 

Φ5

 

⑥ 

PV negative wire 

② 

Charging status LED indicator

 

⑦ 

Battery negative wire 

③ 

Battery status LED indicator 

⑧ 

Load negative wire 

④ 

Temperature Sensor 

*

 

⑨ 

Digital tube 

⑤ 

PV

Battery and Load positive wire

 

⑩ 

Button 

*

 If the temperature sensor short-circuited or damaged, the controller will be 

charging or discharging at the internal temperature of device. 

4. Wiring 

 

 

 

 

 

 

 

 

(1) Connect components to the charge controller in the sequence as shown above and pay 
much attention to the “+” and “-”. Please don’t insert the fuse or turn on the breaker during 
the installation. When disconnecting the system, the order will be reserved. 

(2) After power on the controller, check the battery LED indicator on the controller, it will be 

on solid green. Otherwise please refer to chapter 8. Always connect the battery first, in 

order to allow the controller to recognize the system voltage. 

(3)  The  battery  fuse  should  be  installed  as  close  to  battery  as  possible.  The  suggested 
distance is within 150mm. 

5. LED Indicators 

Indicator 

Color 

Status 

Instruction 

 

Green 

On Solid 

PV connection normal but 

low voltage(irradiance) from 

PV, no charging 

Green 

Slowly Flashing(1Hz) 

In charging 

Green 

Fast Flashing(4Hz) 

PV reverse polarity 

Green 

OFF 

No PV voltage(night time) or 

PV connection problem 

 

Green 

On Solid 

Normal 

Green 

Slowly Flashing(1Hz) 

Full 

Green 

Fast Flashing(4Hz) 

Over voltage 

Orange 

On Solid 

Under voltage 

Red 

On Solid 

Over discharged 

Red 

Fast Flashing(4Hz) 

Battery Overheating 

 

Red 

On Solid 

Load ON 

Red 

OFF 

Load OFF 

Charging  (green)  and  battery  indicator  (orange) 

flashing simultaneously 

Controller overheating 

6. Setting Operation 

 

                                                                               

 

     

 

Button function 

The controller parameters can be set via the button: 

Mode 

Note 

Load ON/OFF   

When the load mode is Manual mode, press the button can turn 
on/off the load. 

Clear error 

Press the button 

Browse Mode 

Press the button and hold on 5s then the digital tube will be on. 
Press the button to roll the item in circle. 

Parameter set 
Mode 

Press the button to roll the item in the browse mode and hold on 5s 
to enter edit parameters with the LED2 flashing. Modify the value by 
pressing the button. Save the data and return to the menu until the 
LED2 stop flash. 

 

Digital Tube Display 

  The reference of LED for parameter and setting value is shown in the table 

LED1 

Item 

LED2 

Value 

Default 

Range 

Battery type 

1

Sealed 

2

Gel   

3

Flooded 

Low voltage disconnect 
voltage

 

10.6V-12.0V Unit 
value=0.1V

x2/24V

 

Load set 

0:Light ON/OFF 
1:Light ON +Timer 
2:Manual Mode 
3:Output mode   
4:Test mode 

Light ON/OFF threshold 
voltage

 

1-17V

x2/24V

   

Light ON+Time mode1:Time1 

0-14H

Unit value= 1H   

Light ON+Time mode2:Time2 

0-14H

Unit value= 1H 

Low Voltage Reconnect Voltage =Low Voltage Disconnect

 

0.5V/12V(x2/24V). 

Radix point of LED segment display indicate the value added “10”, for example 0.=10, 4. =14. 

For  day/night  detection,  load  will  be  automatically  turned  on/off  when  PV  voltage  is 

below/above threshold voltage. 

 

LED Code 

Code

 

Detail 

 

 

Over discharged 

If fault and working state on left appear, 
corresponding code will be displayed. 
Several states occur at the same time, 
these code will be displayed circularly 
(interval  1s).  Only  one  state  occurs,  the 
code  flashes  per  1s.  You  can  enter 
setting mode and set parameters despite 
the error shows

 

 

Under voltage 

 

Load over load

 

 

Load short circuit 

 

The radix point of LED1 lighting up 
indicates that load is ON. 
Oppositely, load is OFF. 

Load  state  (radix  point)  will  conceal 
during  fault  displaying  and  parameter 
setting

 

When load current reaches1.02-1.05 times 1.05-1.25 times, 1.25-1.35 times and 

1.35-1.5 times more than nominal value, controller will automatically close loads in 50s, 

Button 

LED1 

LED2 

Figure 1 Product Feature 

Figure 2 Connection diagram 

 

 

 

Radix point 

 

 

 

 

 

 

 

 

 

 

 

 

Reviews: