8. Troubleshooting
WARNING
:
DO NOT try to repair or maintain the
inverter by own, and it may cause danger.
Phenomenon
Possible reasons
Troubleshooting
Blue indicator
slowly flashing
Buzzer sounds
LCD
display
DC input voltage
under voltage
Measure the DC input voltage
if
the
voltage
is
lower
than10.8/21.6/43.2V.
Adjust
the input voltage to recover
normally.
Blue indicator fast
flashing
Buzzer sounds
LCD
display
DC input voltage
overvoltage
Measure the DC input voltage
if
the
voltage
is
lower
than16/32/64V.
Adjust
the
input
voltage
to
recover
normally.
Red indicator slowly
flashing
Buzzer sounds
LCD
display
Overload
Reduce the number of the
AC load
Restart the inverter
Red indicator fast
flashing
Buzzer sounds
LCD
display
Short circuit
Check carefully loads
connection, clear the fault.
Restart the inverter
Red and blue
indicator on solid
Buzzer sounds
LCD
display
Over-temperature
Improve ventilation quality, do
NOT block the vent, reduce
the temperature around the
power supply, restart the
device after the temperature
drops, if still not working,
please derate the power for
use.