background image

 

 

Electro-Smog (EMF) Detector 

– Radio Frequency detection with enhanced sensitivity – High 

frequency 

– Low frequency – Magnetic field - 1 MHz to 10 GHz frequency range – Detection 3G / 4G / 

5G 

 

  

EPE Conseil would like to thank you for purchasing CEMPROTEC, before using it, please read this guide in its entirety, particularly the "Warnings" section.  
This section specifically indicates the terms of use so that CEMPROTEC is used safely and within the warranty limitations.  
 

 

What is Electro-Smog ?  

We  refer  to  Electro-Smog  as  Electro-Magnetic  Fields  (EMF)  produced  by  technology.  EMFs 

are  “generated  in  the  radiofrequency 

bands  (RF/EMF)  by  popular  wireless  devices  like  cell  phones,  cordless  phones,  baby  monitors,  tablets,  Wi-Fi  enabled  computer 
equipment, cell phone towers/ antenna arrays, radio/television broadcast facilities, and wireless smart meters among others.  EMFs 
are  also  emitted  in  the  extremely  low  frequency  band  (ELF/EMF)  by  electrical  appliances,  electrical  wiring,  and  power  li

nes”.  

(source

https://emfscientist.org

) 

 

 

Operating your detector : the battery 

Insert / changing : when putting the battery in place, please ensure the cable is not placed underneath the battery, but it is 
placed to the side of it.  

Failure to comply with these instructions can damage the cable and cause the compartment lid to not close properly.   

Turning on the device : 

Upon start up the battery level is displayed for 3 seconds then the following functions are set : Loud 

speaker : active / Peak : disactivated

 

Battery level check: 

Upon start up the battery level is displayed for 3 seconds in the middle field row; the 2 other rows are off at this 

point. This bar indicates the battery level with a full green bar representing a full battery. 

 

 

Battery saving mode : 

to save the battery the device will switch itself off automatically after 20 minutes. 

Push buttons :  

·

 POWER button: press to switch on the device  

·

 HF only button/loud speaker : press to active the Peak function  

·

 HF only button/ loud speaker : press and hold for loud speaker  

 
The following table gives further details on the functions :  

Initial state 

Action 

End state 

Device off 

Press the on-off button 

Device is turned on  

Device on 

Press the on-off button  

Device is turned off 

Peak function off 

Press the select button  

Peak function on 

Peak function on 

Press the select button 

Peak function off 

Loud speaker on  

Hold the select button 

Loud speaker is turned off 

Loud speaker off 

Hold the select button 

Loud speaker is turned on 

 
Display values for detection levels: 

The 3 meter views display the levels of disturbance received for the following 3 types of sensors: 

·

 Magnetic 

·

 Electric 

·

 High resolution 

The display is as follows: 

·

 If no disturbance the first green LED will stay lit: 

  
  

 
·

 If a disturbance is detected the level is transcribed with one to two LEDs lit, giving a double level reading. The 8 LEDs therefore allow for 

14 levels in total (see standard mode table). Display example : 

  

 

 

Technical details :

 

Battery powered 9V, non-rechargeable. 
Maximum current : 50mA 
Dimensions : 179,5 x 46 x 32,2 mm 
Weight of the device : 80g 
Ideal temperature usage : -10°C +50°C 
Cleaning recommendations : To clean, use a soft slightly damp cloth with rubbing alcohol.  

 

Warning : 

CEMPROTEC is by no means a measuring device. CEMPROTEC is a detection device that gives tendances and approximations in relation to radiation.  

The human body is likely to directly affect the detection. For a more precise detection, hold the device at least 50 cm away from you.  
The devices are calibrated in an environment at a temperature of 20 ° C and a level of air humidity of 45%. 
Store CEMPROTEC in a dry place with low humidity. 
All modifications to this device are not authorized and will void the warranty.  
Keep out of reach of children.  

 

Quick start guide

 